Enhanced Hotel Room Cleaning: Environmental Microbiological Sampling Investigation in a Midscale Hotel Property

The purpose of our study was to illustrate the efficacy of an enhanced cleaning process during a pandemic by quantifying generic and pathogenic microorganisms before and after cleaning in hotel rooms. The objectives of our study were to: 1) sample high-touch surfaces before and after the rooms were cleaned and 2) swab high-touch surfaces using an adenosine triphosphate (ATP) meter before and after the rooms were cleaned. Overall, 10 rooms and 37 surfaces per room were sampled before and after cleaning. The results showed that several areas of the room had a higher Staphylococcus aureus, aerobic plate, and E.coli/coliform count after cleaning, suggesting that contaminated towels were being used to clean various surfaces in the rooms. In addition, we found no correlation between microbial counts and ATP meter readings. These results show that a more effective method needs to be assessed for practitioners to effectively quantify environmental safety in hotel rooms.

Authors

Institutions

Publication Details

Journal
Journal of environmental health
Published
2025-03-02
DOI
https://doi.org/10.70387/001c.133831
Primary Topic
Conservation Techniques and Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced Hotel Room Cleaning: Environmental Microbiological Sampling Investigation in a Midscale Hotel Property

Zahra H. Mohammad, Alberto Beiza, Sujata A. Sirsat, Cathy Cheatham
Journal of environmental health
Conservation Techniques and Studies
article

Enhanced Hotel Room Cleaning: Environmental Microbiological Sampling Investigation in a Midscale Hotel Property

Zahra H. Mohammad, Alberto Beiza, Sujata A. Sirsat, Cathy Cheatham
article en

Abstract

The purpose of our study was to illustrate the efficacy of an enhanced cleaning process during a pandemic by quantifying generic and pathogenic microorganisms before and after cleaning in hotel rooms. The objectives of our study were to: 1) sample high-touch surfaces before and after the rooms were cleaned and 2) swab high-touch surfaces using an adenosine triphosphate (ATP) meter before and after the rooms were cleaned. Overall, 10 rooms and 37 surfaces per room were sampled before and after cleaning. The results showed that several areas of the room had a higher Staphylococcus aureus, aerobic plate, and E.coli/coliform count after cleaning, suggesting that contaminated towels were being used to clean various surfaces in the rooms. In addition, we found no correlation between microbial counts and ATP meter readings. These results show that a more effective method needs to be assessed for practitioners to effectively quantify environmental safety in hotel rooms.

Journal of environmental healthVol. 87(7)
University of Houston (US)
Openalex Percentile: Top 93%
Conservation Techniques and Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.