Method for Detection and Limitation of Short-Circuit Currents for Semiconductor Circuit Breakers in LVDC Grids Using a Pre-Saturated Inductor

This paper introduces an innovative non-destructive device designed to detect and limit short-circuit currents in LVDC grids. The proposed solution utilizes a transformer fully saturated by a permanent magnet during normal operation. When a short-circuit condition occurs, the transformer desaturates, reducing the rise in current and triggering the detection and protection mechanism. The structure and functionality of the device, along with the design criteria, are discussed. Additionally, optimization measures are presented, examined, and validated. Experimental results from the advanced device prototype demonstrate its effectiveness in detecting and limiting overcurrents. The device features a stable tripping threshold and can safely and reliably interrupt even low time constant capacitive short-circuits. This hardware-based detection solution is ideally suited for installation in a semiconductor circuit breaker.

Authors

Institutions

Publication Details

Journal
IEEE Open Journal of Power Electronics
Published
2025-01-01
DOI
https://doi.org/10.1109/ojpel.2025.3555797
Citations
4
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
2.92
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Method for Detection and Limitation of Short-Circuit Currents for Semiconductor Circuit Breakers in LVDC Grids Using a Pre-Saturated Inductor

Raffael Schwanninger, Vincent Lorentz, Johannes Gehring, Bernd Wunder et al.
4 citations
IEEE Open Journal of Power Electronics
High-Voltage Power Transmission Systems
2.92
article

Method for Detection and Limitation of Short-Circuit Currents for Semiconductor Circuit Breakers in LVDC Grids Using a Pre-Saturated Inductor

Raffael Schwanninger, Vincent Lorentz, Johannes Gehring, Bernd Wunder, Martin Maerz, Alexander Nowak
article en
4 citations

Abstract

This paper introduces an innovative non-destructive device designed to detect and limit short-circuit currents in LVDC grids. The proposed solution utilizes a transformer fully saturated by a permanent magnet during normal operation. When a short-circuit condition occurs, the transformer desaturates, reducing the rise in current and triggering the detection and protection mechanism. The structure and functionality of the device, along with the design criteria, are discussed. Additionally, optimization measures are presented, examined, and validated. Experimental results from the advanced device prototype demonstrate its effectiveness in detecting and limiting overcurrents. The device features a stable tripping threshold and can safely and reliably interrupt even low time constant capacitive short-circuits. This hardware-based detection solution is ideally suited for installation in a semiconductor circuit breaker.

IEEE Open Journal of Power ElectronicsVol. 6
Fraunhofer Institute for Integrated Systems and Device Technology (DE), University of Bayreuth (DE)
Affordable and clean energy
Openalex Percentile: Top 10%
High-Voltage Power Transmission Systems
2.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.