Rapid Dataset-Free Self-Calibration for Heat Flux-Based Core Body Temperature Sensors

This study presents a reference-free calibration method for wearable core body temperature sensors based on the single-heat-flux approach, eliminating the need for a pre-constructed dataset and reducing the required calibration time. In conventional single-heat-flux methods, calibration relies on invasive measurements or numerically generated datasets and typically requires at least 1 h, posing practical challenges. In contrast, the proposed method identifies calibration parameters directly from measured temperature data within approximately 1500 s, which is much quicker than the 3600 s required by existing methods. We validated our method through numerical simulations considering factors such as skin thickness and acceptable measurement errors. These simulations confirmed that the proposed approach reliably achieves adequate calibration without prior dataset construction. Furthermore, we conducted a human subject experiment under resting conditions, where ambient and core body temperature fluctuations, along with heat tolerance responses, were minimal. The results demonstrate that our method can achieve clinically sufficient accuracy in estimating core body temperature, even in the presence of environmental perturbations such as introduced airflow. While the proposed method currently assumes stable conditions and may face challenges in highly dynamic environments involving intense physical activity or significant thermal changes, it marks a critical step toward more accessible and practical wearable core body temperature monitoring. Future work will focus on validating the method with a larger cohort of subjects and integrating additional physiological sensors to enhance reliability and broaden applicability.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3556405
Citations
1
Primary Topic
Infrared Thermography in Medicine
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid Dataset-Free Self-Calibration for Heat Flux-Based Core Body Temperature Sensors

Yuki Hashimoto, Yoshifumi Nishida, Soto Tada
1 citations
IEEE Access
Infrared Thermography in Medicine
1.36
article

Rapid Dataset-Free Self-Calibration for Heat Flux-Based Core Body Temperature Sensors

Yuki Hashimoto, Yoshifumi Nishida, Soto Tada
article en
1 citations

Abstract

This study presents a reference-free calibration method for wearable core body temperature sensors based on the single-heat-flux approach, eliminating the need for a pre-constructed dataset and reducing the required calibration time. In conventional single-heat-flux methods, calibration relies on invasive measurements or numerically generated datasets and typically requires at least 1 h, posing practical challenges. In contrast, the proposed method identifies calibration parameters directly from measured temperature data within approximately 1500 s, which is much quicker than the 3600 s required by existing methods. We validated our method through numerical simulations considering factors such as skin thickness and acceptable measurement errors. These simulations confirmed that the proposed approach reliably achieves adequate calibration without prior dataset construction. Furthermore, we conducted a human subject experiment under resting conditions, where ambient and core body temperature fluctuations, along with heat tolerance responses, were minimal. The results demonstrate that our method can achieve clinically sufficient accuracy in estimating core body temperature, even in the presence of environmental perturbations such as introduced airflow. While the proposed method currently assumes stable conditions and may face challenges in highly dynamic environments involving intense physical activity or significant thermal changes, it marks a critical step toward more accessible and practical wearable core body temperature monitoring. Future work will focus on validating the method with a larger cohort of subjects and integrating additional physiological sensors to enhance reliability and broaden applicability.

IEEE AccessVol. 13
Institute of Science Tokyo (JP)
Casio Science Promotion Foundation, JKA Foundation, Japan Society for the Promotion of Science
Affordable and clean energy
Openalex Percentile: Top 22%
Infrared Thermography in Medicine
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Rapid Dataset-Free Self-Calibration for Heat Flux-Based Core Body Temperature Sensors — Yuki Hashimoto, Yoshifumi Nishida, et al. · IEEE Access (2025) | TGRS Research Map | TGRS