SHAKING TABLE TEST AND ANALYSIS ON EDDY CURRENT DAMPER USING MAGNETIC MATERIAL
Authors discuss the characteristics of eddy current dampers composed of a magnet and a copper plate with magnetic material. Differential integral equations governing both eddy current and magnetization were derived from the Maxwell’s equations and some phenomenological laws. The equations were simplified into a linear simultaneous equation. The results of a shaking table test validated the damping effect and the calculation method of electromagnetic force. Through numerical analysis, the size of the eddy current damper to be applied to a seismically isolated detached house was estimated, and the attractive force acting between the magnet and the steel plate was identified.
Authors
- Takaharu NAKANO (ORCID: https://orcid.org/0000-0002-9492-7135)
- Hisatoshi KASHIWA
- H. Nishimura (ORCID: https://orcid.org/0000-0003-1572-6747)
- Tetsuya UCHIIKE
Institutions
- The University of Osaka (JP)
Publication Details
- Journal
- Journal of Structural Engineering B
- Published
- 2025-01-01
- DOI
- https://doi.org/10.3130/aijjse.71b.0_94
- Primary Topic
- Magnetic Bearings and Levitation Dynamics
- Type
- article
- Field-Weighted Citation Impact
- 0.00