Basic Study on Method of Load Frequency Control in Consideration of BESS Output in Governor-free Control

A load frequency control (LFC) becomes more difficult by the strong growth of renewable power generation. One of the promising measures to support LFC is a battery energy storage system (BESS). Frequency deviation (Δf) can be more effectively suppressed by using BESS for governor-free (GF) control (Case-G) than for Merit-Order based LFC (Case-L). However, kWh capacity of thermal power plants required for LFC in Case-G is larger than those in Case-L because the output of BESS is not taken into account in LFC. Therefore, this study proposes a LFC in consideration of BESS utilization for GF (Case-GFB). As a result, kWh capacity of thermal power plants required for LFC is reduced in Case-G-FB compared to those in Case-G. In addition, the peak of Δf in Case-GFB is a little smaller than those in Case-G because of adjusting the feedback value in consideration of Δf changing property.

Authors

Institutions

Publication Details

Journal
IEEJ Transactions on Power and Energy
Published
2025-03-31
DOI
https://doi.org/10.1541/ieejpes.145.341
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Basic Study on Method of Load Frequency Control in Consideration of BESS Output in Governor-free Control

Shingo Sakaeda, Chiyori T. Urabe, Toshifumi Ise, Takeyoshi Kato et al.
IEEJ Transactions on Power and Energy
Power Systems and Renewable Energy
article

Basic Study on Method of Load Frequency Control in Consideration of BESS Output in Governor-free Control

Shingo Sakaeda, Chiyori T. Urabe, Toshifumi Ise, Takeyoshi Kato, Ryo Yamaguchi
article en

Abstract

A load frequency control (LFC) becomes more difficult by the strong growth of renewable power generation. One of the promising measures to support LFC is a battery energy storage system (BESS). Frequency deviation (Δf) can be more effectively suppressed by using BESS for governor-free (GF) control (Case-G) than for Merit-Order based LFC (Case-L). However, kWh capacity of thermal power plants required for LFC in Case-G is larger than those in Case-L because the output of BESS is not taken into account in LFC. Therefore, this study proposes a LFC in consideration of BESS utilization for GF (Case-GFB). As a result, kWh capacity of thermal power plants required for LFC is reduced in Case-G-FB compared to those in Case-G. In addition, the peak of Δf in Case-GFB is a little smaller than those in Case-G because of adjusting the feedback value in consideration of Δf changing property.

IEEJ Transactions on Power and EnergyVol. 145(4)
Nagoya University (JP), Chubu Electric Power (Japan) (JP)
Openalex Percentile: Top 95%
Power Systems and Renewable Energy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Basic Study on Method of Load Frequency Control in Consideration of BESS Output in Governor-free Control — Shingo Sakaeda, Chiyori T. Urabe, et al. · IEEJ Transactions on Power and Energy (2025) | TGRS Research Map | TGRS