EVALUATION OF EFFECTIVE LENGTH FACTORS FOR NON-UNIFORM FRAME USING STABILITY INDEX

In this study, the effective length factor was calculated using the SI method. Three analytical models were analyzed using the type of column bases, number of stories, number of spans, beam stiffness ratio, stiffness ratio reduction factor and story shear force distribution (Case I, Case II) as analytical parameters for a relatively even non-uniform frame, a frame with severely disturbed column stiffness and a frame with severely disturbed column axial forces, and the effective length factor obtained by the SI method was compared to the effective length factor obtained by the buckling slope-deflection method, and the validity of the SI method was investigated. The results showed that the SI method was able to evaluate the correct value of the effective length factor within an error of about 5% for both analytical models, regardless of the story shear force distribution.

Authors

Institutions

Publication Details

Journal
Journal of Structural Engineering B
Published
2025-01-01
DOI
https://doi.org/10.3130/aijjse.71b.0_251
Citations
1
Primary Topic
Structural Analysis and Optimization
Type
article
Field-Weighted Citation Impact
0.95
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EVALUATION OF EFFECTIVE LENGTH FACTORS FOR NON-UNIFORM FRAME USING STABILITY INDEX

Masae KIDO, Takuma NISHIMURA
1 citations
Journal of Structural Engineering B
Structural Analysis and Optimization
0.95
article

EVALUATION OF EFFECTIVE LENGTH FACTORS FOR NON-UNIFORM FRAME USING STABILITY INDEX

Masae KIDO, Takuma NISHIMURA
article en
1 citations

Abstract

In this study, the effective length factor was calculated using the SI method. Three analytical models were analyzed using the type of column bases, number of stories, number of spans, beam stiffness ratio, stiffness ratio reduction factor and story shear force distribution (Case I, Case II) as analytical parameters for a relatively even non-uniform frame, a frame with severely disturbed column stiffness and a frame with severely disturbed column axial forces, and the effective length factor obtained by the SI method was compared to the effective length factor obtained by the buckling slope-deflection method, and the validity of the SI method was investigated. The results showed that the SI method was able to evaluate the correct value of the effective length factor within an error of about 5% for both analytical models, regardless of the story shear force distribution.

Journal of Structural Engineering BVol. 71B(0)
The University of Kitakyushu (JP)
Climate action
Openalex Percentile: Top 27%
Structural Analysis and Optimization
0.95
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.