Direct Optical Detection of Factor Xa Activity in Minimally Processed Whole Blood

The ability to measure factor Xa activity directly in whole blood samples offers a path toward point-of-care monitoring and personalized anticoagulant dosage, potentially reducing bleeding risk and other anticoagulant-associated complications. We present a strategy to enable direct optical detection of factor Xa in minimally processed whole blood samples. Our strategy relies on a custom FRET-pair labeled DNA-peptide substrate, allowing FRET ratio to be monitored as an indicator of factor Xa activity. Substrates are tethered to a tapered-fiber sensor to allow evanescent detection of fluorescence directly at the sensor surface, minimizing background media interference and enabling detection directly in blood samples. After characterizing the custom substrate and demonstrating the correlation of fiber-based measurements to an existing chromogenic assay, we demonstrate the detection of endogenous factor Xa activity in >85% whole blood. Finally, we demonstrate the detection of therapeutic concentrations of enoxaparin, a widely used anticoagulant, directly in 90% whole blood in less than an hour and correlate these measurements to activated partial thromboplastin time (aPTT) testing. Together, these results indicate a promising strategy to achieve point-of-care factor Xa detection, enabling personalized anticoagulant treatment and reducing adverse outcomes.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-03-31
DOI
https://doi.org/10.1021/acssensors.5c00430
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Direct Optical Detection of Factor Xa Activity in Minimally Processed Whole Blood

H. Tom Soh, Liwei Zheng, Alyssa P. Cartwright, Glaivy Batsuli et al.
ACS Sensors
Atrial Fibrillation Management and Outcomes
article

Direct Optical Detection of Factor Xa Activity in Minimally Processed Whole Blood

H. Tom Soh, Liwei Zheng, Alyssa P. Cartwright, Glaivy Batsuli, Steven Yee, Elizabeth S. York, Benjamin C. Wollant, Huong C. Chau
article en

Abstract

The ability to measure factor Xa activity directly in whole blood samples offers a path toward point-of-care monitoring and personalized anticoagulant dosage, potentially reducing bleeding risk and other anticoagulant-associated complications. We present a strategy to enable direct optical detection of factor Xa in minimally processed whole blood samples. Our strategy relies on a custom FRET-pair labeled DNA-peptide substrate, allowing FRET ratio to be monitored as an indicator of factor Xa activity. Substrates are tethered to a tapered-fiber sensor to allow evanescent detection of fluorescence directly at the sensor surface, minimizing background media interference and enabling detection directly in blood samples. After characterizing the custom substrate and demonstrating the correlation of fiber-based measurements to an existing chromogenic assay, we demonstrate the detection of endogenous factor Xa activity in >85% whole blood. Finally, we demonstrate the detection of therapeutic concentrations of enoxaparin, a widely used anticoagulant, directly in 90% whole blood in less than an hour and correlate these measurements to activated partial thromboplastin time (aPTT) testing. Together, these results indicate a promising strategy to achieve point-of-care factor Xa detection, enabling personalized anticoagulant treatment and reducing adverse outcomes.

ACS SensorsVol. 10(4)
Stanford University (US)
Stanford University, Leona M. and Harry B. Helmsley Charitable Trust, Hemophilia of Georgia, National Heart, Lung, and Blood Institute
Good health and well-being
Openalex Percentile: Top 89%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.