Stress Distribution in Dental Implants under Occlusal Forces – A Digital Simulation.

Aim and objectives: To analyze implant mechanics under loading using Finite Element Analysis (FEA) to assess micro-movements, identify failure points, and optimize design for improved clinical outcomes. Materials and methods: A numerical simulation of mechanical loading on a prosthetic abutment attached to a dental implant was conducted using ANSYS R18.2 Academic®. Measurements, material specifications, and photographs were analyzed to model the implant system with a 6-degree conical connection. Results: Stress analysis under vertical and oblique forces showed all values within permissible titanium alloy limits. Vertical forces led to uniform stress distribution, while oblique forces caused asymmetric stress with localized detachment tendencies. Conclusions: Masticatory forces impact implant stress and may contribute to microleakage, highlighting the need for patient-specific prosthetic alignment.

Authors

Publication Details

Journal
Medicine in Evolution
Published
2025-03-31
DOI
https://doi.org/10.70921/medev.v31i1.1268
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stress Distribution in Dental Implants under Occlusal Forces – A Digital Simulation.

Aviva Petrie, A. C. Novac, Meda Lavinia Negruțiu, Mihai Romînu et al.
Medicine in Evolution
Dental Implant Techniques and Outcomes
article

Stress Distribution in Dental Implants under Occlusal Forces – A Digital Simulation.

Aviva Petrie, A. C. Novac, Meda Lavinia Negruțiu, Mihai Romînu, Cosmin Sinescu, Adelina Elena Stoia, Ioana Elena Lile, Cristian Zaharia, Ioana Veja, Tareq Hajaj, Şerban Talpoş, Florina Titihazan
article en

Abstract

Aim and objectives: To analyze implant mechanics under loading using Finite Element Analysis (FEA) to assess micro-movements, identify failure points, and optimize design for improved clinical outcomes. Materials and methods: A numerical simulation of mechanical loading on a prosthetic abutment attached to a dental implant was conducted using ANSYS R18.2 Academic®. Measurements, material specifications, and photographs were analyzed to model the implant system with a 6-degree conical connection. Results: Stress analysis under vertical and oblique forces showed all values within permissible titanium alloy limits. Vertical forces led to uniform stress distribution, while oblique forces caused asymmetric stress with localized detachment tendencies. Conclusions: Masticatory forces impact implant stress and may contribute to microleakage, highlighting the need for patient-specific prosthetic alignment.

Medicine in EvolutionVol. 31(1)
Openalex Percentile: Top 91%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.