The Effect on Stability Using Max VPC Screw Versus Lag Screw in the Treatment of Mandibular Symphysis Fractures (A Pilot Study)

This study was conducted to assess the hardware installation time, stability of occlusion, and interfragmentary stability following osteosynthesis using MAX VPC screw. A total of 10 patients with symphyseal fractures were included in this study; they were divided into 2 groups of 5; the patients were assessed by Multislice CT scans. The study group received treatment with 2 MAX VPC screws, and the control group received treatment with 2 lag screws. The outcomes that were studied were hardware installation time, stability of occlusion, interfragmentary stability, and pain. The study was conducted on 10 patients, all cases went uneventful, the only significant difference was found in the hardware installation time favoring the study group. In all the other parameters (stability of occlusion, interfragmentary stability, and pain) no statistical difference was recorded. Treatment of symphyseal mandibular fractures with MAX VPC headless compression screws is a valid treatment modality that is comparable to other treatment modalities and presented a faster method of treatment.

Authors

Institutions

Publication Details

Journal
Journal of Craniofacial Surgery
Published
2025-03-31
DOI
https://doi.org/10.1097/scs.0000000000011211
Primary Topic
Facial Trauma and Fracture Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Effect on Stability Using Max VPC Screw Versus Lag Screw in the Treatment of Mandibular Symphysis Fractures (A Pilot Study)

Mohamed Galal Beheiri, Sherif Hamed, Mohamed Khashaba
Journal of Craniofacial Surgery
Facial Trauma and Fracture Management
article

The Effect on Stability Using Max VPC Screw Versus Lag Screw in the Treatment of Mandibular Symphysis Fractures (A Pilot Study)

Mohamed Galal Beheiri, Sherif Hamed, Mohamed Khashaba
article en

Abstract

This study was conducted to assess the hardware installation time, stability of occlusion, and interfragmentary stability following osteosynthesis using MAX VPC screw. A total of 10 patients with symphyseal fractures were included in this study; they were divided into 2 groups of 5; the patients were assessed by Multislice CT scans. The study group received treatment with 2 MAX VPC screws, and the control group received treatment with 2 lag screws. The outcomes that were studied were hardware installation time, stability of occlusion, interfragmentary stability, and pain. The study was conducted on 10 patients, all cases went uneventful, the only significant difference was found in the hardware installation time favoring the study group. In all the other parameters (stability of occlusion, interfragmentary stability, and pain) no statistical difference was recorded. Treatment of symphyseal mandibular fractures with MAX VPC headless compression screws is a valid treatment modality that is comparable to other treatment modalities and presented a faster method of treatment.

Journal of Craniofacial SurgeryVol. 36(4)
Cairo University (EG)
Good health and well-being
Openalex Percentile: Top 89%
Facial Trauma and Fracture Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.