QUALITY CONTROL SYSTEM FOR SAMPLE PREPARATION AND ANALYSIS RESULTS IN THE DIAGNOSIS OF VIRAL HEPATITIS B AND C BY REAL-TIME PCR

Introduction. When conducting diagnostic tests for virus Infection, it is crucial to prevent the false negative results. For this, it is necessary to con-trol all stages of the sample preparation process and the quality of the diagnostic reaction itself. The aim of the work is to create an optimal combination of sample preparation exogenous quality control hepatitis B and C viruses detection sys-tem using real–time multiplex PCR to improve the accuracy, reproducibility and reliability of the results. Material and methods. Hepatitis B virus DNA and hepatitis C virus RNA isolated from blood plasma samples from patients with confirmed diagnoses were used as the object of the study. The following resources were used to perform the in silico study: the online resource Primer-BLAST, integrated in-to the NCBI database; the online service OligoAnalyzer Tool (Integrated DNA Technologies), as well as the programs Oligo Primer Analysis Software, Clustal Omega and UGENE. The CFX96 Touch amplifier (Bio-Rad Laboratories, USA) was used for real-time PCR. PCR was performed using the "HBV In-tifica" and "HCV Intifica" kits (Alkor Bio Group of Companies, Russia). Results. A stable and robust multiplex PCR system has been developed to control the quality of sample preparation and diagnosis of viral hepatitis B and C from human blood plasma. Application of thermodynamic analysis to primers and probes design improves the efficiency of PCR systems, in-creases sensitivity and eliminates false negative results. Conclusions. Thorough optimization of viral primers and probes characteristics, together with application of exogenous internal control in multiplex re-action, significantly improves the accuracy, reproducibility and reliability of analysis results.

Authors

Institutions

Publication Details

Journal
Problems of Biological Medical and Pharmaceutical Chemistry
Published
2025-03-19
DOI
https://doi.org/10.29296/25877313-2025-03-05
Primary Topic
Hepatitis B Virus Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

QUALITY CONTROL SYSTEM FOR SAMPLE PREPARATION AND ANALYSIS RESULTS IN THE DIAGNOSIS OF VIRAL HEPATITIS B AND C BY REAL-TIME PCR

A. V. Moroz, E. B. Aronova, Vassili Toropov, V. N. Bolshakov
Problems of Biological Medical and Pharmaceutical Chemistry
Hepatitis B Virus Studies
article

QUALITY CONTROL SYSTEM FOR SAMPLE PREPARATION AND ANALYSIS RESULTS IN THE DIAGNOSIS OF VIRAL HEPATITIS B AND C BY REAL-TIME PCR

A. V. Moroz, E. B. Aronova, Vassili Toropov, V. N. Bolshakov
article en

Abstract

Introduction. When conducting diagnostic tests for virus Infection, it is crucial to prevent the false negative results. For this, it is necessary to con-trol all stages of the sample preparation process and the quality of the diagnostic reaction itself. The aim of the work is to create an optimal combination of sample preparation exogenous quality control hepatitis B and C viruses detection sys-tem using real–time multiplex PCR to improve the accuracy, reproducibility and reliability of the results. Material and methods. Hepatitis B virus DNA and hepatitis C virus RNA isolated from blood plasma samples from patients with confirmed diagnoses were used as the object of the study. The following resources were used to perform the in silico study: the online resource Primer-BLAST, integrated in-to the NCBI database; the online service OligoAnalyzer Tool (Integrated DNA Technologies), as well as the programs Oligo Primer Analysis Software, Clustal Omega and UGENE. The CFX96 Touch amplifier (Bio-Rad Laboratories, USA) was used for real-time PCR. PCR was performed using the "HBV In-tifica" and "HCV Intifica" kits (Alkor Bio Group of Companies, Russia). Results. A stable and robust multiplex PCR system has been developed to control the quality of sample preparation and diagnosis of viral hepatitis B and C from human blood plasma. Application of thermodynamic analysis to primers and probes design improves the efficiency of PCR systems, in-creases sensitivity and eliminates false negative results. Conclusions. Thorough optimization of viral primers and probes characteristics, together with application of exogenous internal control in multiplex re-action, significantly improves the accuracy, reproducibility and reliability of analysis results.

Problems of Biological Medical and Pharmaceutical Chemistry
Peter the Great St. Petersburg Polytechnic University (RU), Alkor Bio (Russia) (RU)
Openalex Percentile: Top 91%
Hepatitis B Virus Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.