Microfluidic contact lens for continuous monitoring of ocular oxidative stress

Oxidative stress-induced ocular dysfunctions are a significant global health concern. Glutathione (GSH), an abundant antioxidant in tears, can serve as an index for oxidative stress (OS). A coumarin-based fluorescent probe named CCAE was synthesized for GSH monitoring, functioning through structural changes via Michael's addition with GSH and elimination by H<sub>2</sub>O<sub>2</sub>, which restores the conjugation structure to assess the severity of OS-induced ocular diseases. CCAE demonstrated a high sensitivity with a detection limit (LOD) of 0.12 mM and reversibility for 15 cycles. A wearable contact lens sensor was developed featuring a microfluidic lens patterned with a 365 nm pulsed laser, requiring 6 μL of tears. CCAE was encapsulated in citric acid-crosslinked poly(vinyl alcohol) film and embedded in poly((hydroxyethyl)methacrylate-co-ethylene glycol)/polyvinylpyrrolidone (poly(HEMA-co-EG)/PVP) lenses. A customized smartphone readout device enabled quantitative GSH readings for point-of-care applications. Tested on an ex vivo porcine anterior eye model, the sensor achieved an LOD of 0.204 mM, within a detection range of 0.62-1.17 mM and 0.13-0.73 mM under mild and severe OS conditions respectively. The sensors maintained operational stability for 2 days and storage stability for 1 week. This reversible GSH contact lens sensor offers a unique platform for diagnosing and monitoring OS-related ocular conditions at point-of-care settings.

Authors

Institutions

Publication Details

Journal
Biosensors and Bioelectronics
Published
2025-03-31
DOI
https://doi.org/10.1016/j.bios.2025.117427
Citations
7
Primary Topic
Ocular Surface and Contact Lens
Type
article
Field-Weighted Citation Impact
13.15
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microfluidic contact lens for continuous monitoring of ocular oxidative stress

Nan Jiang, Seojung Park, Rona Chandrawati, Savaş Taşoğlu et al.
7 citations
Biosensors and Bioelectronics
Ocular Surface and Contact Lens
13.15
article

Microfluidic contact lens for continuous monitoring of ocular oxidative stress

Nan Jiang, Seojung Park, Rona Chandrawati, Savaş Taşoğlu, Ali K. Yetisen, Yuqi Shi, Angie Davina Tjandra, Yihan Zhang, Yubing Hu
article en
7 citations

Abstract

Oxidative stress-induced ocular dysfunctions are a significant global health concern. Glutathione (GSH), an abundant antioxidant in tears, can serve as an index for oxidative stress (OS). A coumarin-based fluorescent probe named CCAE was synthesized for GSH monitoring, functioning through structural changes via Michael's addition with GSH and elimination by H<sub>2</sub>O<sub>2</sub>, which restores the conjugation structure to assess the severity of OS-induced ocular diseases. CCAE demonstrated a high sensitivity with a detection limit (LOD) of 0.12 mM and reversibility for 15 cycles. A wearable contact lens sensor was developed featuring a microfluidic lens patterned with a 365 nm pulsed laser, requiring 6 μL of tears. CCAE was encapsulated in citric acid-crosslinked poly(vinyl alcohol) film and embedded in poly((hydroxyethyl)methacrylate-co-ethylene glycol)/polyvinylpyrrolidone (poly(HEMA-co-EG)/PVP) lenses. A customized smartphone readout device enabled quantitative GSH readings for point-of-care applications. Tested on an ex vivo porcine anterior eye model, the sensor achieved an LOD of 0.204 mM, within a detection range of 0.62-1.17 mM and 0.13-0.73 mM under mild and severe OS conditions respectively. The sensors maintained operational stability for 2 days and storage stability for 1 week. This reversible GSH contact lens sensor offers a unique platform for diagnosing and monitoring OS-related ocular conditions at point-of-care settings.

Biosensors and BioelectronicsVol. 280
Koç University (TR), West China Medical Center of Sichuan University (CN), UNSW Sydney (AU), Imperial College London (GB)
Openalex Percentile: Top 1%
Ocular Surface and Contact Lens
13.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.