A Structural Optimization Framework for Biodegradable Magnesium Interference Screws

Biodegradable magnesium alloys have garnered increasing attention in recent years, with magnesium alloy-based biomedical devices being clinically used. Unlike biologically inert metallic materials, magnesium-based medical devices degrade during service, resulting in a mechanical structure that evolves over time. However, there are currently few computer-aided engineering methods specifically tailored for magnesium-based medical devices. This paper introduces a structural optimization framework for Mg-1Ca interference screws, accounting for degradation using a continuum damage model (CDM). The Optimal Latin Hypercube Sampling (OLHS) technique was employed to sample within the design space. Pull-out strengths were used as the optimization objective, which were calculated through finite element analysis (FEA). Both Response Surface Methodology (RSM) and Kriging models were employed as surrogate models and optimized using the Sequential Quadratic Programming (SQP) algorithm. The results from the Kriging model were validated through FEA, and were found to be acceptable. The relationships between the design parameters, the rationale behind the methodology, and its limitations are discussed. Finally, a final design is proposed along with recommendations for interference screw design.

Authors

Institutions

Publication Details

Journal
Biomimetics
Published
2025-03-28
DOI
https://doi.org/10.3390/biomimetics10040210
Primary Topic
Magnesium Alloys: Properties and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Structural Optimization Framework for Biodegradable Magnesium Interference Screws

Zhenquan Shen, Ming Zhao, Yafei Li, Xiaochen Zhou
1 links
Biomimetics
Magnesium Alloys: Properties and Applications
article

A Structural Optimization Framework for Biodegradable Magnesium Interference Screws

Zhenquan Shen, Ming Zhao, Yafei Li, Xiaochen Zhou
article en

Abstract

Biodegradable magnesium alloys have garnered increasing attention in recent years, with magnesium alloy-based biomedical devices being clinically used. Unlike biologically inert metallic materials, magnesium-based medical devices degrade during service, resulting in a mechanical structure that evolves over time. However, there are currently few computer-aided engineering methods specifically tailored for magnesium-based medical devices. This paper introduces a structural optimization framework for Mg-1Ca interference screws, accounting for degradation using a continuum damage model (CDM). The Optimal Latin Hypercube Sampling (OLHS) technique was employed to sample within the design space. Pull-out strengths were used as the optimization objective, which were calculated through finite element analysis (FEA). Both Response Surface Methodology (RSM) and Kriging models were employed as surrogate models and optimized using the Sequential Quadratic Programming (SQP) algorithm. The results from the Kriging model were validated through FEA, and were found to be acceptable. The relationships between the design parameters, the rationale behind the methodology, and its limitations are discussed. Finally, a final design is proposed along with recommendations for interference screw design.

BiomimeticsVol. 10(4)
Peking University (CN), Zhengzhou University (CN), Central China Normal University (CN), Schlumberger (United States) (US)
Openalex Percentile: Top 96%
Magnesium Alloys: Properties and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies