Earthquake damage in regions with high seismic risk highlights the need for. measures to improve the earthquake performance of existing structures. One such measure is strengthening these structures to bring them up to the desired performance levels. In this study, the damage to reinforced concrete (RC) buildings was examined in light of the February 6, 2023, Kahramanmaraş (Türkiye) earthquakes to identify the reinforcement needs of RC structures. Numerical analyses were conducted, considering two main factors affecting the shear force capacity in RC columns: low-strength concrete and inadequate transverse reinforcement. The columns were strengthened using four different types of fibre-reinforced polymer (FRP) wrapping, applied to all columns where the shear force was exceeded. The results for the reference building and the four different wrapping methods were compared, and suggestions were made. It was found that all four wrapping methods significantly increased the shear strength capacities of the columns without causing any failure.

Authors

Publication Details

Journal
Advanced Engineering Letters
Published
2025-01-01
DOI
https://doi.org/10.46793/adeletters.2025.4.1.1
Citations
5
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
5.03

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of reinforcement methods with advanced materials for r/c columns

Fatih Avcil, Zouaoui Rabie Harrat, Marijana Hadzima-Nyarko, Enes Arkan et al.
5 citations
Advanced Engineering Letters
Structural Behavior of Reinforced Concrete
5.03
article

Comparison of reinforcement methods with advanced materials for r/c columns

Fatih Avcil, Zouaoui Rabie Harrat, Marijana Hadzima-Nyarko, Enes Arkan, Ercan Işık, Bassam A. Tayeh
article en
5 citations

Abstract

Earthquake damage in regions with high seismic risk highlights the need for. measures to improve the earthquake performance of existing structures. One such measure is strengthening these structures to bring them up to the desired performance levels. In this study, the damage to reinforced concrete (RC) buildings was examined in light of the February 6, 2023, Kahramanmaraş (Türkiye) earthquakes to identify the reinforcement needs of RC structures. Numerical analyses were conducted, considering two main factors affecting the shear force capacity in RC columns: low-strength concrete and inadequate transverse reinforcement. The columns were strengthened using four different types of fibre-reinforced polymer (FRP) wrapping, applied to all columns where the shear force was exceeded. The results for the reference building and the four different wrapping methods were compared, and suggestions were made. It was found that all four wrapping methods significantly increased the shear strength capacities of the columns without causing any failure.

Advanced Engineering LettersVol. 4(1)
European Commission, Erasmus+
Openalex Percentile: Top 5%
Structural Behavior of Reinforced Concrete
5.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparison of reinforcement methods with advanced materials for r/c columns — Fatih Avcil, Zouaoui Rabie Harrat, et al. · Advanced Engineering Letters (2025) | TGRS Research Map | TGRS