An Amplitude Analysis-Based Magnetoelastic Biosensing Method for Quantifying Blood Coagulation

Blood coagulation tests are crucial in the clinical management of cardiovascular diseases and preoperative diagnostics. However, the widespread adoption of existing detection devices, such as thromboelastography (TEG) instruments, is hindered by their bulky size, prohibitive cost, and lengthy detection times. In contrast, magnetoelastic sensors, known for their low cost and rapid response, have garnered attention for their potential application in various coagulation tests. These sensors function by detecting resonant frequency shifts in response to changes in blood viscosity during coagulation. Nevertheless, the frequency-based detection approach necessitates continuous and precise frequency scanning, imposing stringent demands on equipment design, processing, and analytical techniques. In contrast, amplitude-based detection methods offer superior applicability in many sensing scenarios. This paper presents a comprehensive study on signal acquisition from magnetoelastic sensors. We elucidate the mathematical relationship between the resonant amplitude of the response signal and liquid viscosity, propose a quantitative viscosity measurement method based on the maximum amplitude of the signal, and construct a corresponding sensing device. The proposed method was validated using glycerol solutions, demonstrating a sensitivity of 13.83 V<sup>-1</sup>/Pa<sup>0.5</sup>s<sup>0.5</sup>Kg<sup>0.5</sup>m<sup>-1.5</sup> and a detection limit of 0.0817 Pa<sup>0.5</sup>s<sup>0.5</sup>Kg<sup>0.5</sup>m<sup>-1.5</sup>. When applied to real-time monitoring of the coagulation process, the resulting coagulation curves and maximum amplitude (MA) parameters exhibited excellent consistency with standard TEG results (<i>R</i><sup>2</sup> values of 0.9552 and 0.9615, respectively). Additionally, other TEG parameters, such as R-time, K-time, and α-angle, were successfully obtained, effectively reflecting viscosity changes during blood coagulation.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2025-03-29
DOI
https://doi.org/10.3390/bios15040219
Citations
3
Primary Topic
Acoustic Wave Resonator Technologies
Type
article
Field-Weighted Citation Impact
2.02

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Amplitude Analysis-Based Magnetoelastic Biosensing Method for Quantifying Blood Coagulation

Yanjian Liao, Xi Chen, Qiong Wang, Ning Hu et al.
3 citations
Biosensors
Acoustic Wave Resonator Technologies
2.02
article

An Amplitude Analysis-Based Magnetoelastic Biosensing Method for Quantifying Blood Coagulation

Yanjian Liao, Xi Chen, Qiong Wang, Ning Hu, Jun Yang, Jinan Deng
article en
3 citations

Abstract

Blood coagulation tests are crucial in the clinical management of cardiovascular diseases and preoperative diagnostics. However, the widespread adoption of existing detection devices, such as thromboelastography (TEG) instruments, is hindered by their bulky size, prohibitive cost, and lengthy detection times. In contrast, magnetoelastic sensors, known for their low cost and rapid response, have garnered attention for their potential application in various coagulation tests. These sensors function by detecting resonant frequency shifts in response to changes in blood viscosity during coagulation. Nevertheless, the frequency-based detection approach necessitates continuous and precise frequency scanning, imposing stringent demands on equipment design, processing, and analytical techniques. In contrast, amplitude-based detection methods offer superior applicability in many sensing scenarios. This paper presents a comprehensive study on signal acquisition from magnetoelastic sensors. We elucidate the mathematical relationship between the resonant amplitude of the response signal and liquid viscosity, propose a quantitative viscosity measurement method based on the maximum amplitude of the signal, and construct a corresponding sensing device. The proposed method was validated using glycerol solutions, demonstrating a sensitivity of 13.83 V<sup>-1</sup>/Pa<sup>0.5</sup>s<sup>0.5</sup>Kg<sup>0.5</sup>m<sup>-1.5</sup> and a detection limit of 0.0817 Pa<sup>0.5</sup>s<sup>0.5</sup>Kg<sup>0.5</sup>m<sup>-1.5</sup>. When applied to real-time monitoring of the coagulation process, the resulting coagulation curves and maximum amplitude (MA) parameters exhibited excellent consistency with standard TEG results (<i>R</i><sup>2</sup> values of 0.9552 and 0.9615, respectively). Additionally, other TEG parameters, such as R-time, K-time, and α-angle, were successfully obtained, effectively reflecting viscosity changes during blood coagulation.

BiosensorsVol. 15(4)
Chongqing University (CN), Chongqing Medical and Pharmaceutical College (CN)
National Natural Science Foundation of China
Good health and well-being
Openalex Percentile: Top 15%
Acoustic Wave Resonator Technologies
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.