Einfluss der Hornhautbiomechanik auf die Ortho-K-Anpassung

Purpose. The aim of this clinical observation was to investigate the influence of corneal biomechanics on the fitting of orthokeratology contact lenses. Material and Methods. The measurements were performed in a single-center, longitudinal user observation with n = 17 subjects aged 18 to 43 years. Refraction and corneal topography were determined during the initial examination. Biomechanical parameters such as strain-stress index (SSI) and stiffness parameters (SP-A1) were recorded using Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany). After wearing the contact lenses for the first time, four two-day consecutive follow-up appointments followed to document the decrease in the spherical equivalent and the corneal radii. At the last appointment, the corneal biomechanics were recorded again. Results. The initial results showed a mean distribution of the spherical equivalent of −2.38 ± 0.95 D and a mean distribution of the apical corneal radius of 7.64 ± 0.26 mm and 7.71 ± 0.26 mm of the flat corneal radius. The corneal biomechanical parameters were 1.12 ± 0.17 (SSI) and 101.86 ± 11.71 mmHg (SP-A1). Changes in the parameters (SEQ, apical and flat corneal radius) occurred in the adaptation process, especially in the very high and low stiffnesses between the third and seventh night. Corneal biomechanics also changed as a result of adaptation (p < 0.001). The mean SSI was 1.12 ± 0.17 at baseline and 1.05 ± 0.16 after the seventh night. The stiffness parameter was 101.86 ± 11.71 mmHg at baseline and 105.45 ± 11.34 mmHg after the seventh night. Conclusion. Fundamental changes in the orthokeratologic effect were recorded by corneal biomechanics. The adjustment of corneal biomechanics during Ortho-K treatment allows conclusions to be drawn about the orthokeratologic effect, but these are only possible after a certain period of time.

Authors

Publication Details

Journal
Optometry & contact lenses
Published
2025-03-28
DOI
https://doi.org/10.54352/dozv.klnw5680
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Einfluss der Hornhautbiomechanik auf die Ortho-K-Anpassung

Matteo Sutter, Silke Waltemath, Sebastian Schubert
Optometry & contact lenses
Glaucoma and retinal disorders
article

Einfluss der Hornhautbiomechanik auf die Ortho-K-Anpassung

Matteo Sutter, Silke Waltemath, Sebastian Schubert
article en

Abstract

Purpose. The aim of this clinical observation was to investigate the influence of corneal biomechanics on the fitting of orthokeratology contact lenses. Material and Methods. The measurements were performed in a single-center, longitudinal user observation with n = 17 subjects aged 18 to 43 years. Refraction and corneal topography were determined during the initial examination. Biomechanical parameters such as strain-stress index (SSI) and stiffness parameters (SP-A1) were recorded using Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany). After wearing the contact lenses for the first time, four two-day consecutive follow-up appointments followed to document the decrease in the spherical equivalent and the corneal radii. At the last appointment, the corneal biomechanics were recorded again. Results. The initial results showed a mean distribution of the spherical equivalent of −2.38 ± 0.95 D and a mean distribution of the apical corneal radius of 7.64 ± 0.26 mm and 7.71 ± 0.26 mm of the flat corneal radius. The corneal biomechanical parameters were 1.12 ± 0.17 (SSI) and 101.86 ± 11.71 mmHg (SP-A1). Changes in the parameters (SEQ, apical and flat corneal radius) occurred in the adaptation process, especially in the very high and low stiffnesses between the third and seventh night. Corneal biomechanics also changed as a result of adaptation (p < 0.001). The mean SSI was 1.12 ± 0.17 at baseline and 1.05 ± 0.16 after the seventh night. The stiffness parameter was 101.86 ± 11.71 mmHg at baseline and 105.45 ± 11.34 mmHg after the seventh night. Conclusion. Fundamental changes in the orthokeratologic effect were recorded by corneal biomechanics. The adjustment of corneal biomechanics during Ortho-K treatment allows conclusions to be drawn about the orthokeratologic effect, but these are only possible after a certain period of time.

Optometry & contact lensesVol. 5(3)
Openalex Percentile: Top 89%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.