Melt Electrowritten Biodegradable Mesh Implants with Auxetic Designs for Pelvic Organ Prolapse Repair

Pelvic organ prolapse (POP) is a common condition among women, characterized by the descent of pelvic organs through the vaginal canal. Although traditional synthetic meshes are widely utilized, they are associated with complications such as erosion, infection, and tissue rejection. This study explores the design and fabrication of biodegradable auxetic implants using polycaprolactone and melt electrowriting technology, with the goal of developing implants that closely replicate the mechanical behavior of vaginal tissue while minimizing implant-related complications. Four distinct auxetic mesh geometries—re-entrant Evans, Lozenge grid, square grid, and three-star honeycomb—were fabricated with a 160 μm diameter and mechanically evaluated through uniaxial tensile testing. The results indicate that the square grid and three-star honeycomb geometries exhibit hyperelastic-like behavior, closely mimicking the stress–strain response of vaginal tissue. The re-entrant Evans geometry has been observed to exhibit excessive stiffness for applications related to POP, primarily due to material overlap. This geometry demonstrates stiffness that is approximately five times greater than that of the square grid or the three-star honeycomb configurations, which contributes to an increase in local rigidity. The unique auxetic properties of these structures prevent the bundling effect observed in synthetic meshes, promoting improved load distribution and minimizing the risk of tissue compression. Additionally, increasing the extrusion diameter has been identified as a promising strategy for further refining the biomechanical properties of these meshes. These findings lay a solid foundation for the development of next-generation biodegradable implants.

Authors

Institutions

Publication Details

Journal
Journal of Manufacturing and Materials Processing
Published
2025-03-28
DOI
https://doi.org/10.3390/jmmp9040111
Citations
2
Primary Topic
Ergonomics and Musculoskeletal Disorders
Type
article
Field-Weighted Citation Impact
4.88
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Melt Electrowritten Biodegradable Mesh Implants with Auxetic Designs for Pelvic Organ Prolapse Repair

António Augusto Fernandes, Maria Elisabete Silva, Marco Parente, António L.L. da Silva et al.
2 citations
Journal of Manufacturing and Materials Processing
Ergonomics and Musculoskeletal Disorders
4.88
article

Melt Electrowritten Biodegradable Mesh Implants with Auxetic Designs for Pelvic Organ Prolapse Repair

António Augusto Fernandes, Maria Elisabete Silva, Marco Parente, António L.L. da Silva, Ana Telma Silva, Nuno Miguel Ferreira, Evangelia Antoniadi
article en
2 citations

Abstract

Pelvic organ prolapse (POP) is a common condition among women, characterized by the descent of pelvic organs through the vaginal canal. Although traditional synthetic meshes are widely utilized, they are associated with complications such as erosion, infection, and tissue rejection. This study explores the design and fabrication of biodegradable auxetic implants using polycaprolactone and melt electrowriting technology, with the goal of developing implants that closely replicate the mechanical behavior of vaginal tissue while minimizing implant-related complications. Four distinct auxetic mesh geometries—re-entrant Evans, Lozenge grid, square grid, and three-star honeycomb—were fabricated with a 160 μm diameter and mechanically evaluated through uniaxial tensile testing. The results indicate that the square grid and three-star honeycomb geometries exhibit hyperelastic-like behavior, closely mimicking the stress–strain response of vaginal tissue. The re-entrant Evans geometry has been observed to exhibit excessive stiffness for applications related to POP, primarily due to material overlap. This geometry demonstrates stiffness that is approximately five times greater than that of the square grid or the three-star honeycomb configurations, which contributes to an increase in local rigidity. The unique auxetic properties of these structures prevent the bundling effect observed in synthetic meshes, promoting improved load distribution and minimizing the risk of tissue compression. Additionally, increasing the extrusion diameter has been identified as a promising strategy for further refining the biomechanical properties of these meshes. These findings lay a solid foundation for the development of next-generation biodegradable implants.

Journal of Manufacturing and Materials ProcessingVol. 9(4)
Universidade do Porto (PT), Institute of Mechanical Engineering and Industrial Mangement (PT)
Openalex Percentile: Top 7%
Ergonomics and Musculoskeletal Disorders
4.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.