Optical Fiber Methane Sensor Based on Mach–Zehnder Interferometer Induced by Multimode Interference

In this paper, based on the multimode interference structure fiber and the sensitive advantages of a zeolitic imidazolate framework-8/Polydimethylsiloxane (ZIF-8/PDMS)-sensitive film in methane detection, a methane sensor based on an interferometer induced by multimode interference is designed and built with the aid of modeling. The methane-sensitive single mode fiber (MS-SMF) is obtained by coating a ZIF-8/PDMS-sensitive film around the cladding of a thin-diameter SMF. The change in methane concentration leads to a change in the cladding mode of the MS-SMF, which causes a change in interference spectrum and realizes methane concentration sensing. The factors affecting the sensitivity of the methane sensor are analyzed. Methane sensors with various parameters are fabricated and tested on a methane sensor platform for performance estimation at methane concentrations of 0-4%. The experimental results show that the sensitivity of the sensor to methane reaches 2.364 nm/% when the length of the MS-SMF is 42 mm, the thickness of the sensitive film is 1.8 µm, and the diameter of the MS-SMF is 58 µm. The limit of detection is about 338 ppm. The average response time is 30 s and the recovery time is 45 s. The temperature sensitivity of the methane sensor is approximately 0.026 nm/°C. The experimental results verify the correctness of the methane sensor model. This study provides a new design idea for optical methane sensors, showing great application potential in the field of methane detection.

Authors

Institutions

Publication Details

Journal
Micromachines
Published
2025-03-29
DOI
https://doi.org/10.3390/mi16040406
Citations
1
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.76

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optical Fiber Methane Sensor Based on Mach–Zehnder Interferometer Induced by Multimode Interference

Yan Li, Yating Hu, Fuling Yang, Xinghan Li et al.
1 citations
Micromachines
Spectroscopy and Laser Applications
0.76
article

Optical Fiber Methane Sensor Based on Mach–Zehnder Interferometer Induced by Multimode Interference

Yan Li, Yating Hu, Fuling Yang, Xinghan Li, Yuanyuan Qu, Jing Wang, Zelong Wang, Sicheng Zong
article en
1 citations

Abstract

In this paper, based on the multimode interference structure fiber and the sensitive advantages of a zeolitic imidazolate framework-8/Polydimethylsiloxane (ZIF-8/PDMS)-sensitive film in methane detection, a methane sensor based on an interferometer induced by multimode interference is designed and built with the aid of modeling. The methane-sensitive single mode fiber (MS-SMF) is obtained by coating a ZIF-8/PDMS-sensitive film around the cladding of a thin-diameter SMF. The change in methane concentration leads to a change in the cladding mode of the MS-SMF, which causes a change in interference spectrum and realizes methane concentration sensing. The factors affecting the sensitivity of the methane sensor are analyzed. Methane sensors with various parameters are fabricated and tested on a methane sensor platform for performance estimation at methane concentrations of 0-4%. The experimental results show that the sensitivity of the sensor to methane reaches 2.364 nm/% when the length of the MS-SMF is 42 mm, the thickness of the sensitive film is 1.8 µm, and the diameter of the MS-SMF is 58 µm. The limit of detection is about 338 ppm. The average response time is 30 s and the recovery time is 45 s. The temperature sensitivity of the methane sensor is approximately 0.026 nm/°C. The experimental results verify the correctness of the methane sensor model. This study provides a new design idea for optical methane sensors, showing great application potential in the field of methane detection.

MicromachinesVol. 16(4)
China University of Mining and Technology (CN)
National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities
Affordable and clean energy
Openalex Percentile: Top 33%
Spectroscopy and Laser Applications
0.76
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.