Multistage Cyclic Dielectrophoresis for High-Resolution Sorting of Submicron Particles

The precise preparation and application of nanomicrospheres is currently an emerging research hotspot in the cutting-edge cross-disciplines. As an important functional material, nanosized microspheres show a broad application prospect in biomedicine, chemical engineering, materials science, and other fields. However, microspheres with good monodispersity are still facing technical bottlenecks, such as complicated preparation process and high cost. In this study, a multistage cyclic dielectrophoresis (MC-DEP) technique is innovatively proposed to successfully realize the high-resolution sorting of submicron microspheres. A dielectrophoresis chip adopts a unique electrode design, in which the electrodes are arranged at the top and bottom of the microchannel at the same time. This symmetric electrode structure effectively eliminates the difference in the distribution of dielectrophoretic force in the perpendicular direction and ensures the homogeneity of the initial state of particle sorting. Three pairs of focusing electrodes are in the front section of the microchannel for preaggregation of the microspheres, and the deflection electrodes in the back section are to realize particle size sorting. After this, the upper and lower limits of particle size are limited by multiple cycles of sorting. The multistage cyclic sorting increases the stability of particle deflection under dielectrophoretic forces and reduces the error perturbation caused by the fluid environment. The experimental results show that the multistage cycling sorting scheme significantly improves the monodispersity of the microspheres, and the coefficient of variation of the particle size is significantly reduced from the initial 12.3% to 5.4% after three cycles of sorting, which fully verifies the superior performance of this technology.

Authors

Institutions

Publication Details

Journal
Micromachines
Published
2025-03-29
DOI
https://doi.org/10.3390/mi16040404
Primary Topic
Microfluidic and Bio-sensing Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multistage Cyclic Dielectrophoresis for High-Resolution Sorting of Submicron Particles

Hui You, Wangxi Luo, Cuimin Sun, Zekun Li et al.
Micromachines
Microfluidic and Bio-sensing Technologies
article

Multistage Cyclic Dielectrophoresis for High-Resolution Sorting of Submicron Particles

Hui You, Wangxi Luo, Cuimin Sun, Zekun Li, Chaowen Zheng
article en

Abstract

The precise preparation and application of nanomicrospheres is currently an emerging research hotspot in the cutting-edge cross-disciplines. As an important functional material, nanosized microspheres show a broad application prospect in biomedicine, chemical engineering, materials science, and other fields. However, microspheres with good monodispersity are still facing technical bottlenecks, such as complicated preparation process and high cost. In this study, a multistage cyclic dielectrophoresis (MC-DEP) technique is innovatively proposed to successfully realize the high-resolution sorting of submicron microspheres. A dielectrophoresis chip adopts a unique electrode design, in which the electrodes are arranged at the top and bottom of the microchannel at the same time. This symmetric electrode structure effectively eliminates the difference in the distribution of dielectrophoretic force in the perpendicular direction and ensures the homogeneity of the initial state of particle sorting. Three pairs of focusing electrodes are in the front section of the microchannel for preaggregation of the microspheres, and the deflection electrodes in the back section are to realize particle size sorting. After this, the upper and lower limits of particle size are limited by multiple cycles of sorting. The multistage cyclic sorting increases the stability of particle deflection under dielectrophoretic forces and reduces the error perturbation caused by the fluid environment. The experimental results show that the multistage cycling sorting scheme significantly improves the monodispersity of the microspheres, and the coefficient of variation of the particle size is significantly reduced from the initial 12.3% to 5.4% after three cycles of sorting, which fully verifies the superior performance of this technology.

MicromachinesVol. 16(4)
Guangxi University (CN), Beihai People's Hospital (CN)
Openalex Percentile: Top 94%
Microfluidic and Bio-sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.