THE EFFECT OF BEARING SURFACE ON CEMENTLESS AND HYBRID TOTAL HIP ARTHROPLASTY SURVIVAL: AN UPDATED ANALYSIS OF CONTEMPORARY BEARING DATA FROM THE NATIONAL JOINT REGISTRY AND HOSPITAL EPISODE STATISTICS

The aim of this project was to analyse the effect of contemporary THR bearings on THA survival. This is an updated report of our previous analysis with longer follow up and now includes antioxidant-stabilised polyethylene bearings. We combined the NJR dataset with polyethylene manufacturing properties to sub-divide polyethylene into conventional (PE) and highly crosslinked (XLPE). Only THAs with a cementless acetabular component were included. The Hospital Episode Statistics (HES) dataset was used to link ipsilateral surgical procedures for the treatment of peri-prosthetic hip fractures. Reoperation for peri-prosthetic fracture was defined as revision as registered by the NJR or fixation as captured by the HES dataset. Cause-specific and overall reasons for revisions were analysed using Kaplan-Meier and multi-variate Cox proportional hazard regression survival analyses. A total of 696,013 THAs and 17,468 reoperations were included in this analysis. Regression analysis with metal on XLPE as the reference bearing adjusted for age, sex, stem fixation and head size revealed that the lowest risk of revision for any reason was in Ceramicised Metal on XLPE (HR= 0.77, 95% CI = 0.69 – 0.86) followed by Ceramic on Antioxidant XLPE (HR 0.78, 95%CI = 0.68 – 0.88), Ceramic on XLPE (HR= 0.86, 95%CI = 0.82 – 0.91), Ceramic on Ceramic (HR 0.95, 95%CI= 0.90 – 1.0) and Metal on Antioxidant XLPE (HR 1.02, 95%CI= 1.05 – 1.14). Age under 55 at primary, male sex, cementless stem fixation and head size of 28mm were associated with a higher risk of revision. In this updated report with longer follow up, XLPE-based bearings were associated with the lowest risk of revision. The lowest risk of revision for aseptic loosening and revision for all reasons was in CMoXLPE THAs.

Authors

Institutions

Publication Details

Journal
Orthopaedic Proceedings
Published
2025-03-31
DOI
https://doi.org/10.1302/1358-992x.2025.2.004
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

THE EFFECT OF BEARING SURFACE ON CEMENTLESS AND HYBRID TOTAL HIP ARTHROPLASTY SURVIVAL: AN UPDATED ANALYSIS OF CONTEMPORARY BEARING DATA FROM THE NATIONAL JOINT REGISTRY AND HOSPITAL EPISODE STATISTICS

Edward T. Davis, Alistair McGuire, Michael Drummond, Joseph Pagkalos et al.
Orthopaedic Proceedings
Orthopaedic implants and arthroplasty
article

THE EFFECT OF BEARING SURFACE ON CEMENTLESS AND HYBRID TOTAL HIP ARTHROPLASTY SURVIVAL: AN UPDATED ANALYSIS OF CONTEMPORARY BEARING DATA FROM THE NATIONAL JOINT REGISTRY AND HOSPITAL EPISODE STATISTICS

Edward T. Davis, Alistair McGuire, Michael Drummond, Joseph Pagkalos, Maria Raikou
article en

Abstract

The aim of this project was to analyse the effect of contemporary THR bearings on THA survival. This is an updated report of our previous analysis with longer follow up and now includes antioxidant-stabilised polyethylene bearings. We combined the NJR dataset with polyethylene manufacturing properties to sub-divide polyethylene into conventional (PE) and highly crosslinked (XLPE). Only THAs with a cementless acetabular component were included. The Hospital Episode Statistics (HES) dataset was used to link ipsilateral surgical procedures for the treatment of peri-prosthetic hip fractures. Reoperation for peri-prosthetic fracture was defined as revision as registered by the NJR or fixation as captured by the HES dataset. Cause-specific and overall reasons for revisions were analysed using Kaplan-Meier and multi-variate Cox proportional hazard regression survival analyses. A total of 696,013 THAs and 17,468 reoperations were included in this analysis. Regression analysis with metal on XLPE as the reference bearing adjusted for age, sex, stem fixation and head size revealed that the lowest risk of revision for any reason was in Ceramicised Metal on XLPE (HR= 0.77, 95% CI = 0.69 – 0.86) followed by Ceramic on Antioxidant XLPE (HR 0.78, 95%CI = 0.68 – 0.88), Ceramic on XLPE (HR= 0.86, 95%CI = 0.82 – 0.91), Ceramic on Ceramic (HR 0.95, 95%CI= 0.90 – 1.0) and Metal on Antioxidant XLPE (HR 1.02, 95%CI= 1.05 – 1.14). Age under 55 at primary, male sex, cementless stem fixation and head size of 28mm were associated with a higher risk of revision. In this updated report with longer follow up, XLPE-based bearings were associated with the lowest risk of revision. The lowest risk of revision for aseptic loosening and revision for all reasons was in CMoXLPE THAs.

Orthopaedic ProceedingsVol. 107-B(SUPP_2)
Royal Orthopaedic Hospital (GB), University of York (GB), University of Birmingham (GB), London School of Economics and Political Science (GB)
Openalex Percentile: Top 89%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.