Evaluation of Non-Faradaic Impedimetric Parameters for IL-8 Detection Using Gold Interdigitated Electrode-Based Biosensors: Towards Early Detection of Newborn Disability

Interleukin-8 (IL-8) is a critical biomarker associated with inflammation and disability in both adults and newborns. Conventional detection methods are often labor-intensive, time-consuming, and require highly trained personnel. Non-Faradaic impedimetric biosensors offer a label-free, rapid, and direct approach for IL-8 detection. While previous studies have primarily focused on capacitance and phase changes, the potential of other impedimetric parameters remains underexplored. In this study, a gold interdigitated electrode (Au-IDE)-based non-Faradaic biosensor was developed for IL-8 detection, evaluating multiple impedimetric parameters, including capacitance, impedance magnitude (Z<sub>mod</sub>), real impedance (Z<sub>real</sub>), and imaginary impedance (Z<sub>imag</sub>). Among these, Z<sub>imag</sub> exhibited the lowest limit of detection (LoD) at 90 pg/mL, followed by Z<sub>mod</sub> at 120 pg/mL, and capacitance at 140 pg/mL, all significantly below the clinical threshold of 600 pg/mL. In contrast, Z<sub>real</sub> displayed the highest LoD at 1.3 ng/mL. Sensitivity analysis revealed that Z<sub>imag</sub> provided the highest sensitivity at 13.1 kΩ/log (ng/mL), making it the most effective parameter for detecting IL-8 at low concentrations. The sensitivity of Z<sub>mod</sub> and Z<sub>real</sub> was lower, while capacitance sensitivity was measured at 20 nF/log (ng/mL). These findings highlight the importance of investigating alternative impedimetric parameters beyond capacitance to optimize biosensor performance for biomarker detection. This study demonstrates that non-Faradaic biosensors, despite their capacitive-based nature, can achieve enhanced sensitivity and detection limits by leveraging additional impedimetric parameters, offering a promising approach for rapid and effective IL-8 detection.

Authors

Institutions

Publication Details

Journal
Micromachines
Published
2025-03-28
DOI
https://doi.org/10.3390/mi16040395
Citations
2
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
1.61

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Non-Faradaic Impedimetric Parameters for IL-8 Detection Using Gold Interdigitated Electrode-Based Biosensors: Towards Early Detection of Newborn Disability

Abdulaziz K. Assaifan, Hend Alfadul, Abdulelah S. Alrebaish, Amir Altinawi et al.
2 citations
Micromachines
Advanced biosensing and bioanalysis techniques
1.61
article

Evaluation of Non-Faradaic Impedimetric Parameters for IL-8 Detection Using Gold Interdigitated Electrode-Based Biosensors: Towards Early Detection of Newborn Disability

Abdulaziz K. Assaifan, Hend Alfadul, Abdulelah S. Alrebaish, Amir Altinawi, Layla O. Alnami, Joud M. Alshraim, Razan A. Alnghemshi, Alanoud A. Aljammaz, Kholood K. Alhuthali
article en
2 citations

Abstract

Interleukin-8 (IL-8) is a critical biomarker associated with inflammation and disability in both adults and newborns. Conventional detection methods are often labor-intensive, time-consuming, and require highly trained personnel. Non-Faradaic impedimetric biosensors offer a label-free, rapid, and direct approach for IL-8 detection. While previous studies have primarily focused on capacitance and phase changes, the potential of other impedimetric parameters remains underexplored. In this study, a gold interdigitated electrode (Au-IDE)-based non-Faradaic biosensor was developed for IL-8 detection, evaluating multiple impedimetric parameters, including capacitance, impedance magnitude (Z<sub>mod</sub>), real impedance (Z<sub>real</sub>), and imaginary impedance (Z<sub>imag</sub>). Among these, Z<sub>imag</sub> exhibited the lowest limit of detection (LoD) at 90 pg/mL, followed by Z<sub>mod</sub> at 120 pg/mL, and capacitance at 140 pg/mL, all significantly below the clinical threshold of 600 pg/mL. In contrast, Z<sub>real</sub> displayed the highest LoD at 1.3 ng/mL. Sensitivity analysis revealed that Z<sub>imag</sub> provided the highest sensitivity at 13.1 kΩ/log (ng/mL), making it the most effective parameter for detecting IL-8 at low concentrations. The sensitivity of Z<sub>mod</sub> and Z<sub>real</sub> was lower, while capacitance sensitivity was measured at 20 nF/log (ng/mL). These findings highlight the importance of investigating alternative impedimetric parameters beyond capacitance to optimize biosensor performance for biomarker detection. This study demonstrates that non-Faradaic biosensors, despite their capacitive-based nature, can achieve enhanced sensitivity and detection limits by leveraging additional impedimetric parameters, offering a promising approach for rapid and effective IL-8 detection.

MicromachinesVol. 16(4)
King Saud University (SA), King Salman Center for Disability Research (SA)
King Salman Center for Disability Research
Decent work and economic growth
Openalex Percentile: Top 18%
Advanced biosensing and bioanalysis techniques
1.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.