Dependence of parallel imaging with linear predictability on the undersampling direction

Parallel imaging with linear predictability takes advantage of information present in multiple receive coils to accurately reconstruct the image with fewer samples. Commonly used algorithms based on linear predictability include GRAPPA and SPIRiT. We present a sufficient condition for an accurate reconstruction based on the direction of undersampling and the arrangement of the sensing coils. We show, with examples, that the quality of the reconstruction can be high or low for the same data based on whether this condition is met or not met, respectively. We also propose a metric—the acceleration direction metric (ADM)—that uses a fully sampled region centered on the 0 frequency to identify which direction(s) of undersampling would allow for a good-quality image reconstruction prior to full data collection.

Authors

Institutions

Publication Details

Journal
Journal of Electronic Imaging
Published
2025-03-31
DOI
https://doi.org/10.1117/1.jei.34.2.023031
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dependence of parallel imaging with linear predictability on the undersampling direction

Alex McManus, Nicholas Dwork, Stephen Becker
Journal of Electronic Imaging
Optical Imaging and Spectroscopy Techniques
article

Dependence of parallel imaging with linear predictability on the undersampling direction

Alex McManus, Nicholas Dwork, Stephen Becker
article en

Abstract

Parallel imaging with linear predictability takes advantage of information present in multiple receive coils to accurately reconstruct the image with fewer samples. Commonly used algorithms based on linear predictability include GRAPPA and SPIRiT. We present a sufficient condition for an accurate reconstruction based on the direction of undersampling and the arrangement of the sensing coils. We show, with examples, that the quality of the reconstruction can be high or low for the same data based on whether this condition is met or not met, respectively. We also propose a metric—the acceleration direction metric (ADM)—that uses a fully sampled region centered on the 0 frequency to identify which direction(s) of undersampling would allow for a good-quality image reconstruction prior to full data collection.

Journal of Electronic ImagingVol. 34(02)
University of Colorado Boulder (US), University of Colorado System (US), University of Colorado Anschutz Medical Campus (US)
Openalex Percentile: Top 90%
Optical Imaging and Spectroscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines