The Experimental Determination of RQR 3, 4 and 5 - Specific HVL Values within Romania’s SSDL, IFIN-HH

This study experimentally determines the half-value layers (HVL) for RQR 3, RQR 4, and RQR 5 X-ray beams at Romania's Secondary Standard Dosimetry Laboratory (SSDL). RQR beams, standardized by the IEC for radiology calibration, correspond to specific tube voltage and filtration settings, simulating clinical conditions. Simplified parameters like tube voltage and HVLs describe the beam’s spectral distribution. HVL measurements ensure compliance with international standards in radioprotection and medical imaging. Following guidelines from IAEA TRS-457 and ISO/IEC 61267, the results confirm alignment with published data and improve calibration processes in radiology.

Authors

Publication Details

Journal
Romanian Journal of Physics
Published
2025-03-15
DOI
https://doi.org/10.59277/romjphys.2025.70.901
Primary Topic
Cytokine Signaling Pathways and Interactions
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Experimental Determination of RQR 3, 4 and 5 - Specific HVL Values within Romania’s SSDL, IFIN-HH

BADEA R.-A., ORIAN A.-Ș., VOICU A.-M., G. PAȚĂ et al.
Romanian Journal of Physics
Cytokine Signaling Pathways and Interactions
article

The Experimental Determination of RQR 3, 4 and 5 - Specific HVL Values within Romania’s SSDL, IFIN-HH

BADEA R.-A., ORIAN A.-Ș., VOICU A.-M., G. PAȚĂ, S. PĂTRAȘCU, IOAN M.-R.
article en

Abstract

This study experimentally determines the half-value layers (HVL) for RQR 3, RQR 4, and RQR 5 X-ray beams at Romania's Secondary Standard Dosimetry Laboratory (SSDL). RQR beams, standardized by the IEC for radiology calibration, correspond to specific tube voltage and filtration settings, simulating clinical conditions. Simplified parameters like tube voltage and HVLs describe the beam’s spectral distribution. HVL measurements ensure compliance with international standards in radioprotection and medical imaging. Following guidelines from IAEA TRS-457 and ISO/IEC 61267, the results confirm alignment with published data and improve calibration processes in radiology.

Romanian Journal of PhysicsVol. 70(1-2)
Ministerul Cercetării, Inovării şi Digitalizării
Openalex Percentile: Top 91%
Cytokine Signaling Pathways and Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Experimental Determination of RQR 3, 4 and 5 - Specific HVL Values within Romania’s SSDL, IFIN-HH — BADEA R.-A., ORIAN A.-Ș., et al. · Romanian Journal of Physics (2025) | TGRS Research Map | TGRS