Life-cycle thermo-economic-environmental analysis of a PV-driven heat pump with and without refrigerant leakages

Achieving near-zero emissions by 2050 requires residential air-conditioning systems to integrate renewable energy sources, aligning with energy community principles. Additionally, the forthcoming F-Gas regulation will phase out fluorinated gases in domestic heat-pumps, promoting natural refrigerants like propane. However, heat pump performances may degrade up to 50 % overtime due to undetected soft faults, such as refrigerant leakage. These aspects make the optimization of future small-scale heat pumps coupled with renewables challenging, since optimal total cost and environmental impact solutions may diverge. This paper presents a multi-criteria analysis for a 2.5 kW domestic heat-pump driven by photovoltaic solar panels. A preliminary design optimization compared two refrigerants, R32 and propane, by permuting several design parameters, revealing 25–32 % lower production costs for R32 compared to propane. Optimal designs were then simulated over their lifetime, considering varying photovoltaic panel and battery sizes, European climates and refrigerant leakage scenarios. Results confirm a misalignment between cost-minimizing and environmentally optimal solutions, underscoring the need for incentive politics aimed at reducing design costs. However, these policies may be insufficient under high refrigerant leakage scenarios, having 11 %–20 % cost increase, and 70 %–85 % life cycle climate performance increase with the fault-free case. Therefore, fault detection, diagnosis and evaluation strategies become essential. • Small size air-source heat pumps driven by photovoltaic solar panels. • Design optimization of geometrical characteristics of the standalone heat pump. • Seasonal multi-objective optimization of solar collector and storage battery sizes. • Misalignment of solutions yielding minimum total costs and environmental impact. • Cost/Environment misalignment rises with refrigerant leakages, detection tools needed.

Authors

Institutions

Publication Details

Journal
Energy
Published
2025-03-31
DOI
https://doi.org/10.1016/j.energy.2025.135894
Citations
9
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
6.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Life-cycle thermo-economic-environmental analysis of a PV-driven heat pump with and without refrigerant leakages

Luca Viscito, Francesco Pelella, A.W. Mauro, Adelso Flaviano Passarelli
9 citations
Energy
Refrigeration and Air Conditioning Technologies
6.42
article

Life-cycle thermo-economic-environmental analysis of a PV-driven heat pump with and without refrigerant leakages

Luca Viscito, Francesco Pelella, A.W. Mauro, Adelso Flaviano Passarelli
article en
9 citations

Abstract

Achieving near-zero emissions by 2050 requires residential air-conditioning systems to integrate renewable energy sources, aligning with energy community principles. Additionally, the forthcoming F-Gas regulation will phase out fluorinated gases in domestic heat-pumps, promoting natural refrigerants like propane. However, heat pump performances may degrade up to 50 % overtime due to undetected soft faults, such as refrigerant leakage. These aspects make the optimization of future small-scale heat pumps coupled with renewables challenging, since optimal total cost and environmental impact solutions may diverge. This paper presents a multi-criteria analysis for a 2.5 kW domestic heat-pump driven by photovoltaic solar panels. A preliminary design optimization compared two refrigerants, R32 and propane, by permuting several design parameters, revealing 25–32 % lower production costs for R32 compared to propane. Optimal designs were then simulated over their lifetime, considering varying photovoltaic panel and battery sizes, European climates and refrigerant leakage scenarios. Results confirm a misalignment between cost-minimizing and environmentally optimal solutions, underscoring the need for incentive politics aimed at reducing design costs. However, these policies may be insufficient under high refrigerant leakage scenarios, having 11 %–20 % cost increase, and 70 %–85 % life cycle climate performance increase with the fault-free case. Therefore, fault detection, diagnosis and evaluation strategies become essential. • Small size air-source heat pumps driven by photovoltaic solar panels. • Design optimization of geometrical characteristics of the standalone heat pump. • Seasonal multi-objective optimization of solar collector and storage battery sizes. • Misalignment of solutions yielding minimum total costs and environmental impact. • Cost/Environment misalignment rises with refrigerant leakages, detection tools needed.

EnergyVol. 323
University of Naples Federico II (IT)
Responsible consumption and production
Openalex Percentile: Top 3%
Refrigeration and Air Conditioning Technologies
6.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.