Precision Spectroscopy of Antiprotonic Atoms for Investigation of Low-energy Antinucleon–nucleus Interactions

We propose a high-precision x-ray spectroscopy experiment of antiprotonic atoms to advance the understanding of low-energy antinucleon-nucleus interactions. The current leading model of antiproton-nucleus interactions is based on an optical potential with parameters derived from a global fit to antiprotonic atom x-ray data across the periodic table. However, the isovector parameter of this potential remains poorly constrained due to uncertainties in nucleon distributions of the nuclei. To address this, we propose to use calcium isotopes with well-studied nucleon distributions to minimize these uncertainties. A superconducting microcalorimeter detector will provide a resolution of 50–70 eV in the energy range of interest, allowing high-precision determination of the isotope-dependent strong-interaction shifts and widths. The outcomes of the proposed experiment can be used to refine the model of antinucleon-nucleus interactions and provide critical data for future experiments searching for neutron-antineutron oscillations.

Authors

Publication Details

Published
2025-03-31
DOI
https://doi.org/10.22323/1.480.0049
Primary Topic
Nuclear physics research studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Precision Spectroscopy of Antiprotonic Atoms for Investigation of Low-energy Antinucleon–nucleus Interactions

Takashi Higuchi, Hiroyuki Fujioka
Nuclear physics research studies
article

Precision Spectroscopy of Antiprotonic Atoms for Investigation of Low-energy Antinucleon–nucleus Interactions

Takashi Higuchi, Hiroyuki Fujioka
article en

Abstract

We propose a high-precision x-ray spectroscopy experiment of antiprotonic atoms to advance the understanding of low-energy antinucleon-nucleus interactions. The current leading model of antiproton-nucleus interactions is based on an optical potential with parameters derived from a global fit to antiprotonic atom x-ray data across the periodic table. However, the isovector parameter of this potential remains poorly constrained due to uncertainties in nucleon distributions of the nuclei. To address this, we propose to use calcium isotopes with well-studied nucleon distributions to minimize these uncertainties. A superconducting microcalorimeter detector will provide a resolution of 50–70 eV in the energy range of interest, allowing high-precision determination of the isotope-dependent strong-interaction shifts and widths. The outcomes of the proposed experiment can be used to refine the model of antinucleon-nucleus interactions and provide critical data for future experiments searching for neutron-antineutron oscillations.

Openalex Percentile: Top 97%
Nuclear physics research studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.