SIMULATION OF THE PROCESS OF MEASURING THE FLOW RATE OF A PULSATING LIQUID FLOW THROUGH AN EXPANDING DEVICE
The article presents the results of modeling a differential pressure flowmeter with a flow transducer in the form of an expanding device that measures the flow rate of a pulsating liquid. The article describes a method for obtaining basic modified equations for describing models and presents the structure of the flow transducer. A conical diffuser is used as an expanding flow transducer in operation. In this article, a model of such a flow meter is obtained and the factors influencing the process of measuring the pulsating flow rate of a liquid are investigated. An estimation of the uncertainty of measuring results of the pulsating flow rate using such a transducer is given. The factors influencing the accuracy of flow measurement are investigated.
Authors
- Zh.A. Dayev (ORCID: https://orcid.org/0000-0002-7685-2862)
- А.К. Кайракбаев (ORCID: https://orcid.org/0000-0002-4416-4782)
Publication Details
- Journal
- Herald of Kazakh-British technical university
- Published
- 2025-03-27
- DOI
- https://doi.org/10.55452/1998-6688-2025-22-1-307-317
- Primary Topic
- Flow Measurement and Analysis
- Type
- article
- Field-Weighted Citation Impact
- 0.00