Comparison of in vivo ankle joint kinematics after total ankle replacement with different types of talar components

Implant loosening and sinking are the primary reasons for revision surgery following total ankle arthroplasty (TAA). Utilizing a custom-made artificial talar prosthesis in conjunction with TAA (combined TAA) is anticipated to address these issues. However, few studies have investigated in vivo ankle joint kinematics after TAA with an artificial talar prosthesis, and there is a need to evaluate and compare this newer approach with conventional talar implants, which only replace the articular surface of the talus (standard TAA). This study aimed to compare postoperative ankle joint kinematics in vivo between standard TAA and combined TAA. Twenty-six orthopedic patients who underwent TAA participated in this study (standard TAA: 9; combined TAA: 17). Computed tomography (CT) of the ankle was performed in non-weight-bearing maximal dorsiflexion and plantarflexion. In vivo ankle joint kinematics during these movements were calculated using three-dimensional implant models created from CT images and registered with the iterative closest point algorithm. The transitional motion from dorsiflexion to plantarflexion and the implant position and posture at each ankle position were assessed. There was no significant difference in the transition angles from dorsiflexion to plantarflexion between the standard and combined TAA groups. After combined TAA, the ankle joints exhibited a posture of more inclined inversion and abduction, and the implant position and posture did not significantly impact the postoperative range of motion. Although the sample size was insufficient for statistical analysis because of the rarity of the surgery, these findings offer insights for future implant design and surgical techniques.

Authors

Institutions

Publication Details

Journal
Journal of Biomechanics
Published
2025-03-31
DOI
https://doi.org/10.1016/j.jbiomech.2025.112665
Primary Topic
Foot and Ankle Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of in vivo ankle joint kinematics after total ankle replacement with different types of talar components

Hiroshi Takemura, Shin‐ichi Kosugi, Masataka Yamamoto, Yasuhito Tanaka et al.
Journal of Biomechanics
Foot and Ankle Surgery
article

Comparison of in vivo ankle joint kinematics after total ankle replacement with different types of talar components

Hiroshi Takemura, Shin‐ichi Kosugi, Masataka Yamamoto, Yasuhito Tanaka, Hiroaki Kurokawa, Rea Ikeda
article en

Abstract

Implant loosening and sinking are the primary reasons for revision surgery following total ankle arthroplasty (TAA). Utilizing a custom-made artificial talar prosthesis in conjunction with TAA (combined TAA) is anticipated to address these issues. However, few studies have investigated in vivo ankle joint kinematics after TAA with an artificial talar prosthesis, and there is a need to evaluate and compare this newer approach with conventional talar implants, which only replace the articular surface of the talus (standard TAA). This study aimed to compare postoperative ankle joint kinematics in vivo between standard TAA and combined TAA. Twenty-six orthopedic patients who underwent TAA participated in this study (standard TAA: 9; combined TAA: 17). Computed tomography (CT) of the ankle was performed in non-weight-bearing maximal dorsiflexion and plantarflexion. In vivo ankle joint kinematics during these movements were calculated using three-dimensional implant models created from CT images and registered with the iterative closest point algorithm. The transitional motion from dorsiflexion to plantarflexion and the implant position and posture at each ankle position were assessed. There was no significant difference in the transition angles from dorsiflexion to plantarflexion between the standard and combined TAA groups. After combined TAA, the ankle joints exhibited a posture of more inclined inversion and abduction, and the implant position and posture did not significantly impact the postoperative range of motion. Although the sample size was insufficient for statistical analysis because of the rarity of the surgery, these findings offer insights for future implant design and surgical techniques.

Journal of BiomechanicsVol. 188
Tokyo University of Science (JP), Osaka Nishi Clinic (JP), Nara Medical University (JP)
Openalex Percentile: Top 92%
Foot and Ankle Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.