Performance indicators for portable X-ray fluorescence devices

The invention of hand-held X-ray fluorescence devices (HH-XRF) has revolutionized the way we analyse ancient materials. These devices are equipped with highly miniaturized hardware and advanced software, which encourages users to consider them as black boxes. This enables archaeologists, art historians, and restorers to be self-sufficient in performing materials analysis. However, there are specific situations, such as the investigation of copper-based artefacts, where users need to have a deeper understanding of the device's functioning. This article discusses the experiments carried out to reconfigure a hand-held Bruker Tracer 5g from scratch, compare it with an in-house developed portable spectrometer, and prepare both devices for field use. We focus on optimizing the primary filters and calibrating the devices by considering two quantitative parameters: the limit of quantification and the relative uncertainty of quantification.

Authors

Institutions

Publication Details

Journal
ACTA IMEKO
Published
2025-03-17
DOI
https://doi.org/10.21014/actaimeko.v14i1.1864
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance indicators for portable X-ray fluorescence devices

Roberto Ferretti, Simone Porcinai, M. Ferretti, Annalaura Casanova Municchia et al.
4 links
ACTA IMEKO
Medical Imaging Techniques and Applications
article

Performance indicators for portable X-ray fluorescence devices

Roberto Ferretti, Simone Porcinai, M. Ferretti, Annalaura Casanova Municchia, Eleni Konstantakopoulou
article en

Abstract

The invention of hand-held X-ray fluorescence devices (HH-XRF) has revolutionized the way we analyse ancient materials. These devices are equipped with highly miniaturized hardware and advanced software, which encourages users to consider them as black boxes. This enables archaeologists, art historians, and restorers to be self-sufficient in performing materials analysis. However, there are specific situations, such as the investigation of copper-based artefacts, where users need to have a deeper understanding of the device's functioning. This article discusses the experiments carried out to reconfigure a hand-held Bruker Tracer 5g from scratch, compare it with an in-house developed portable spectrometer, and prepare both devices for field use. We focus on optimizing the primary filters and calibrating the devices by considering two quantitative parameters: the limit of quantification and the relative uncertainty of quantification.

ACTA IMEKOVol. 14(1)
Roma Tre University (IT), Direção Geral do Património Cultural (PT)
Erasmus+
Openalex Percentile: Top 90%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.