The use of Apple smartwatches to obtain vital signs readings in surgical patients

Wearable devices, such as Apple smartwatches, have been widely used for medical and healthcare purposes. Although they provide a wide array of applications, such as heart rate and oxygen saturation determination, only a few studies have demonstrated the reliability and accuracy of these devices. Hence, this study aimed to assess the reliability of the Apple smartwatch series 8 (ASWs8) in determining heart rate and oxygen saturation against conventional monitoring devices (CMD). This cross-section study encompassed a cohort of 52 patients from King Abdulaziz University Dental Hospital in Jeddah, Saudi Arabia. We collected heart rate and oxygen saturation data via the ASWs8 and CMD. Subsequently, the mean measurement of each parameter was compared and evaluated for any significant differences. The ASWs8 yielded a mean heart rate measurement of 83.04 ± 13.4 BPM, while CMD produced 82.81 ± 13.5 BPM. The mean difference stood at - 0.23 ± 0.7 BPM, with limits of agreement ranging from - 25 to 25%. No significant difference emerged in the determination of heart rate (Cronbach α = 0.999, p = 0.311). Additionally, the ASWs8 recorded an average oxygen saturation measurement of 97.10 ± 1.6%, compared to CMD's 98.23 ± 1.0%. This resulted in a mean difference of 0.74% and limits of agreement spanning from - 3 to 1%. Once again, the analysis unveiled that no statistically significant difference existed in the obtained oxygen saturation levels (Cronbach α = 0.735, p = 0.094). In this study, we have uncovered compelling evidence that the ASWs8 stands as a reliable and accurate device. It exhibits strong concordance with the CMD, rendering it suitable for continuous vital signs, particularly for heart rate and oxygen saturation. Furthermore, this device can play a pivotal role in clinical management, facilitating the early detection of abnormal physiological parameters among pre-operative patients, thereby potentially reducing hospital admissions.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-03-29
DOI
https://doi.org/10.1038/s41598-024-84459-0
Citations
2
Primary Topic
Mobile Health and mHealth Applications
Type
article
Field-Weighted Citation Impact
5.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The use of Apple smartwatches to obtain vital signs readings in surgical patients

Mohammed Nadershah, Amr Bayoumi, Othman Bawajeeh, Razan M. Baabdullah et al.
2 citations
Scientific Reports
Mobile Health and mHealth Applications
5.63
article

The use of Apple smartwatches to obtain vital signs readings in surgical patients

Mohammed Nadershah, Amr Bayoumi, Othman Bawajeeh, Razan M. Baabdullah, Shadi Alzahrani, Mohammed Alghamdi, Mohammed Bayoumi, Amal M. Alghamdi
article en
2 citations

Abstract

Wearable devices, such as Apple smartwatches, have been widely used for medical and healthcare purposes. Although they provide a wide array of applications, such as heart rate and oxygen saturation determination, only a few studies have demonstrated the reliability and accuracy of these devices. Hence, this study aimed to assess the reliability of the Apple smartwatch series 8 (ASWs8) in determining heart rate and oxygen saturation against conventional monitoring devices (CMD). This cross-section study encompassed a cohort of 52 patients from King Abdulaziz University Dental Hospital in Jeddah, Saudi Arabia. We collected heart rate and oxygen saturation data via the ASWs8 and CMD. Subsequently, the mean measurement of each parameter was compared and evaluated for any significant differences. The ASWs8 yielded a mean heart rate measurement of 83.04 ± 13.4 BPM, while CMD produced 82.81 ± 13.5 BPM. The mean difference stood at - 0.23 ± 0.7 BPM, with limits of agreement ranging from - 25 to 25%. No significant difference emerged in the determination of heart rate (Cronbach α = 0.999, p = 0.311). Additionally, the ASWs8 recorded an average oxygen saturation measurement of 97.10 ± 1.6%, compared to CMD's 98.23 ± 1.0%. This resulted in a mean difference of 0.74% and limits of agreement spanning from - 3 to 1%. Once again, the analysis unveiled that no statistically significant difference existed in the obtained oxygen saturation levels (Cronbach α = 0.735, p = 0.094). In this study, we have uncovered compelling evidence that the ASWs8 stands as a reliable and accurate device. It exhibits strong concordance with the CMD, rendering it suitable for continuous vital signs, particularly for heart rate and oxygen saturation. Furthermore, this device can play a pivotal role in clinical management, facilitating the early detection of abnormal physiological parameters among pre-operative patients, thereby potentially reducing hospital admissions.

Scientific ReportsVol. 15(1)
Pharos University in Alexandria (EG), King Abdulaziz University (SA), King Abdul Aziz University Hospital (SA), Alexandria University (EG)
Quality Education
Openalex Percentile: Top 6%
Mobile Health and mHealth Applications
5.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.