Development of Non-Enzymatic Glucose Sensor Using Ag-Au Bimetallic Modified Pencil Lead Electrode with Voltammetry Method

Glucose is an essential monosaccharide that serves as the main source of energy in the human body. An imbalance in glucose levels in the body can lead to serious metabolic disorders, such as diabetes mellitus. Therefore, effective methods of analyzing and monitoring glucose levels are needed for early detection and more optimal disease management. In this study, a non-enzymatic glucose sensor based on Pencil Lead Electrode (PLE) modified with silver-gold (Ag-Au) bimetallic was developed through electrodeposition method using cyclic voltammetry. This modification aims to improve sensitivity and cost efficiency in glucose detection compared to enzymatic sensors, that are susceptible to denaturation and higher production costs. Electrodeposition is performed in a potential range of 1.6 V to -0.4 V to obtain an optimal bimetallic coating on the PLE surface. The Ag-Au/PLE electrode provided the best electrochemical response in detecting glucose, with oxidation and re-oxidation peaks at +0.01 V in 0.1 M KOH as a supporting electrolyte. The optimal condition was obtained in five electrodeposition cycles, with a correlation coefficient value of 0.9984 and a detection limit of 0.206 mM, indicating high sensitivity and accuracy. These results indicate that Ag-Au/PLE electrodes have great potential as reliable, sensitive and economical non-enzymatic glucose sensors.

Authors

Institutions

Publication Details

Journal
IJCA (Indonesian Journal of Chemical Analysis)
Published
2025-03-30
DOI
https://doi.org/10.20885/ijca.vol8.iss1.art9
Citations
1
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of Non-Enzymatic Glucose Sensor Using Ag-Au Bimetallic Modified Pencil Lead Electrode with Voltammetry Method

Trisna Kumala Sari, Alizar Alizar, Romy Dwipa Yamesa Away, Rahmida Marlini
1 citations
IJCA (Indonesian Journal of Chemical Analysis)
Electrochemical sensors and biosensors
0.73
article

Development of Non-Enzymatic Glucose Sensor Using Ag-Au Bimetallic Modified Pencil Lead Electrode with Voltammetry Method

Trisna Kumala Sari, Alizar Alizar, Romy Dwipa Yamesa Away, Rahmida Marlini
article en
1 citations

Abstract

Glucose is an essential monosaccharide that serves as the main source of energy in the human body. An imbalance in glucose levels in the body can lead to serious metabolic disorders, such as diabetes mellitus. Therefore, effective methods of analyzing and monitoring glucose levels are needed for early detection and more optimal disease management. In this study, a non-enzymatic glucose sensor based on Pencil Lead Electrode (PLE) modified with silver-gold (Ag-Au) bimetallic was developed through electrodeposition method using cyclic voltammetry. This modification aims to improve sensitivity and cost efficiency in glucose detection compared to enzymatic sensors, that are susceptible to denaturation and higher production costs. Electrodeposition is performed in a potential range of 1.6 V to -0.4 V to obtain an optimal bimetallic coating on the PLE surface. The Ag-Au/PLE electrode provided the best electrochemical response in detecting glucose, with oxidation and re-oxidation peaks at +0.01 V in 0.1 M KOH as a supporting electrolyte. The optimal condition was obtained in five electrodeposition cycles, with a correlation coefficient value of 0.9984 and a detection limit of 0.206 mM, indicating high sensitivity and accuracy. These results indicate that Ag-Au/PLE electrodes have great potential as reliable, sensitive and economical non-enzymatic glucose sensors.

IJCA (Indonesian Journal of Chemical Analysis)Vol. 8(1)
State University of Padang (ID)
Openalex Percentile: Top 30%
Electrochemical sensors and biosensors
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.