Modification of Screen-Printed Carbon Electrode (SPCE) by Magnetic Fe3O4-Chitosan for Detection of Hexavalent Chromium

A new modification of screen-printed carbon electrode (SPCE) with magnetic Fe3O4-chitosan has been developed. Magnetic Fe3O4-chitosan was made from a mixture of Fe2+/Fe3+ (1:2) with 1% chitosan. Sodium tripolyphosphate was used as a crosslinking reagent for chitosan under alkaline conditions using NH3. SPCE modification with Fe3O4 can increase the sensitivity of Cr(VI) detection by differential pulse voltammetry (DPV). This method resulted in a sensitivity of 21.9 ppm/μA in the 0.1 - 1 ppm Cr(VI) concentration range in a 0.005 M KCl-HCl electrolyte mixture. The detection limit (LoD) is 0.2 ppm with an average accuracy of 94%.

Authors

Institutions

Publication Details

Journal
IJCA (Indonesian Journal of Chemical Analysis)
Published
2025-03-30
DOI
https://doi.org/10.20885/ijca.vol8.iss1.art8
Citations
1
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modification of Screen-Printed Carbon Electrode (SPCE) by Magnetic Fe3O4-Chitosan for Detection of Hexavalent Chromium

Yuniar Ponco Prananto, Ani Mulyasuryani
1 citations
IJCA (Indonesian Journal of Chemical Analysis)
Electrochemical sensors and biosensors
0.73
article

Modification of Screen-Printed Carbon Electrode (SPCE) by Magnetic Fe3O4-Chitosan for Detection of Hexavalent Chromium

Yuniar Ponco Prananto, Ani Mulyasuryani
article en
1 citations

Abstract

A new modification of screen-printed carbon electrode (SPCE) with magnetic Fe3O4-chitosan has been developed. Magnetic Fe3O4-chitosan was made from a mixture of Fe2+/Fe3+ (1:2) with 1% chitosan. Sodium tripolyphosphate was used as a crosslinking reagent for chitosan under alkaline conditions using NH3. SPCE modification with Fe3O4 can increase the sensitivity of Cr(VI) detection by differential pulse voltammetry (DPV). This method resulted in a sensitivity of 21.9 ppm/μA in the 0.1 - 1 ppm Cr(VI) concentration range in a 0.005 M KCl-HCl electrolyte mixture. The detection limit (LoD) is 0.2 ppm with an average accuracy of 94%.

IJCA (Indonesian Journal of Chemical Analysis)Vol. 8(1)
University of Brawijaya (ID)
Openalex Percentile: Top 30%
Electrochemical sensors and biosensors
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.