Corrosion of Concrete Structures Exposed to Industrial Coal-Fired Flue Gas

Coal combustion of industrial production will release large amounts of SO<sub>2</sub> and CO<sub>2</sub> gases. High concentrations of acidic gases will accelerate the deterioration of concrete corrosion, leading to premature failure or damage to structures. To investigate the corrosion behavior of concrete structures exposed to industrial coal-fired flue gas for 12 years, this paper tested the concrete's macro-mechanical properties, pore structure characteristics, and micro-properties by in-situ and laboratory tests along the height and depth. The test results indicated that the concrete exhibited significant uneven corrosion along the height of the structure. In the severely attacked region (28.6-39.1 m), the neutralization depth in the concrete was 1.4 times greater than that in the slightly attacked region (0-6.6 m), and the porosity was 5 times higher. Different corrosion mechanisms were occurred inside the concrete along the corrosion depth direction. In the shallow concrete zone (0-8 mm), sulfation was predominant, with gypsum (Gyp) as the primary product. The pH was below 8.0, and the sulfate ion (<inline-graphic specific-use="online" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="./online/j.gyjzG24092302-I003.jpg" href="./online/j.gyjzG24092302-I003.jpg"/>) concentration at the exposure surface reached up to 5.5%. In the coexistence concrete zone (8-14 mm), both sulfation and carbonation were presented, with the pH increasing from 8.0 to 11.0. Above 14 mm, <inline-graphic specific-use="online" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="./online/j.gyjzG24092302-I004.jpg" href="./online/j.gyjzG24092302-I004.jpg"/> and Gyp were no longer detected. At 10 mm, calcium carbonate (CaCO<sub>3</sub>) was found, and its content gradually increased. In the deep concrete zone (14-18 mm), carbonation was the dominant process, with CaCO<sub>3</sub> as the main product.

Authors

Publication Details

Journal
Industrial Construction
Published
2025-01-01
DOI
https://doi.org/10.3724/j.gyjzg24092302
Primary Topic
Concrete Corrosion and Durability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Corrosion of Concrete Structures Exposed to Industrial Coal-Fired Flue Gas

Ditao Niu, Teng Yang, Xiguang Liu, Peng Gao et al.
Industrial Construction
Concrete Corrosion and Durability
article

Corrosion of Concrete Structures Exposed to Industrial Coal-Fired Flue Gas

Ditao Niu, Teng Yang, Xiguang Liu, Peng Gao, Liang Guo, Gaolin Zhufu
article en

Abstract

Coal combustion of industrial production will release large amounts of SO<sub>2</sub> and CO<sub>2</sub> gases. High concentrations of acidic gases will accelerate the deterioration of concrete corrosion, leading to premature failure or damage to structures. To investigate the corrosion behavior of concrete structures exposed to industrial coal-fired flue gas for 12 years, this paper tested the concrete's macro-mechanical properties, pore structure characteristics, and micro-properties by in-situ and laboratory tests along the height and depth. The test results indicated that the concrete exhibited significant uneven corrosion along the height of the structure. In the severely attacked region (28.6-39.1 m), the neutralization depth in the concrete was 1.4 times greater than that in the slightly attacked region (0-6.6 m), and the porosity was 5 times higher. Different corrosion mechanisms were occurred inside the concrete along the corrosion depth direction. In the shallow concrete zone (0-8 mm), sulfation was predominant, with gypsum (Gyp) as the primary product. The pH was below 8.0, and the sulfate ion (<inline-graphic specific-use="online" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="./online/j.gyjzG24092302-I003.jpg" href="./online/j.gyjzG24092302-I003.jpg"/>) concentration at the exposure surface reached up to 5.5%. In the coexistence concrete zone (8-14 mm), both sulfation and carbonation were presented, with the pH increasing from 8.0 to 11.0. Above 14 mm, <inline-graphic specific-use="online" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="./online/j.gyjzG24092302-I004.jpg" href="./online/j.gyjzG24092302-I004.jpg"/> and Gyp were no longer detected. At 10 mm, calcium carbonate (CaCO<sub>3</sub>) was found, and its content gradually increased. In the deep concrete zone (14-18 mm), carbonation was the dominant process, with CaCO<sub>3</sub> as the main product.

Industrial ConstructionVol. 55(1)
Sustainable cities and communities
Openalex Percentile: Top 94%
Concrete Corrosion and Durability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Corrosion of Concrete Structures Exposed to Industrial Coal-Fired Flue Gas — Ditao Niu, Teng Yang, et al. · Industrial Construction (2025) | TGRS Research Map | TGRS