Seismocardiograph Monitoring Using SMS Fiber Structure with PDMS Enclosure

This study presents a novel seismocardiography (SCG) monitoring system utilizing a singlemode-multimode-singlemode (SMS) fiber structure encased within a polydimethylsiloxane (PDMS) enclosure. The system employs a simple intensity-based interrogation method. Experimental characterization of the SMS fiber sensor demonstrated its sensitivity to vibrations, achieving an average calibration error of 1.63%. Validation against a gold-standard electrocardiogram (ECG) yielded an average error of 2.29%, representing a 1.27% accuracy improvement over existing fiber-optic SCG sensors (97.71% vs. 96.48%). This design offers a simplified and more robust alternative to current fiber-optic SCG sensors while maintaining high accuracy.

Authors

Institutions

Publication Details

Journal
Journal of Biomedical Photonics & Engineering
Published
2025-03-20
DOI
https://doi.org/10.18287/jbpe25.11.010303
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Seismocardiograph Monitoring Using SMS Fiber Structure with PDMS Enclosure

Dhany Arifianto, Frans Rizal Agustiyanto, Selfi Stendafity, Maulana Santoso et al.
Journal of Biomedical Photonics & Engineering
Non-Invasive Vital Sign Monitoring
article

Seismocardiograph Monitoring Using SMS Fiber Structure with PDMS Enclosure

Dhany Arifianto, Frans Rizal Agustiyanto, Selfi Stendafity, Maulana Santoso, Agus Muhamad Hatta, Budi Susetyo Pikir, Mahenda Radityo
article en

Abstract

This study presents a novel seismocardiography (SCG) monitoring system utilizing a singlemode-multimode-singlemode (SMS) fiber structure encased within a polydimethylsiloxane (PDMS) enclosure. The system employs a simple intensity-based interrogation method. Experimental characterization of the SMS fiber sensor demonstrated its sensitivity to vibrations, achieving an average calibration error of 1.63%. Validation against a gold-standard electrocardiogram (ECG) yielded an average error of 2.29%, representing a 1.27% accuracy improvement over existing fiber-optic SCG sensors (97.71% vs. 96.48%). This design offers a simplified and more robust alternative to current fiber-optic SCG sensors while maintaining high accuracy.

Journal of Biomedical Photonics & EngineeringVol. 11(1)
Sepuluh Nopember Institute of Technology (ID), Universitas Airlangga (ID)
Openalex Percentile: Top 94%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Seismocardiograph Monitoring Using SMS Fiber Structure with PDMS Enclosure — Dhany Arifianto, Frans Rizal Agustiyanto, et al. · Journal of Biomedical Photonics & Engineering (2025) | TGRS Research Map | TGRS