Accurate measurement of a bone surrogate flexural rigidity in three- and four-point bending

The mechanical assessment of long bones through bending is an established preclinical approach to evaluate the effectiveness of treatments for osteoporosis and fractures. Three- and four-point bending (3PB and 4PB) tests are the most common methods for mechanical characterization of long bones with Euler-Bernoulli (EB) theory to calculate of bone flexural rigidity (EI). Previous studies demonstrated that EB theory underestimates the EI of long bones due to its reliance on assumptions that are not entirely applicable to long bones. Therefore, the current study aimed to evaluate the factors that affect the percent error (PE) and bias stemming from the omission of contact and shear deflections in the EI estimation using mechanical testing and finite element analysis (FEA). The true EI of a porcine bone surrogate was used to quantify the percent error and bias of EI estimations from three deflection measurement methods and FEA, in 3PB and 4PB. The analysis confirmed that bending was the main component of total deflection, but only contributed to approximately 50 % and 65 % of the total deflection in 3PB and 4PB, respectively. The combined shear and indentation deflections accounted for the remainder of the total deflection. The FEA aligned with 3PB and 4PB tests with less than 10 % deviation. Underestimation of EI was largest with deflection measurements taken from the machine crosshead (PE 74 % in 3PB and 71 % in 4PB). However, these underestimations improved notably when indentation and shear deflections were considered (PE 42 % in 3PB and 39 % in 4PB). The deflection measurements from extensometer and digital image correlation (DIC) underestimated the EI by 66 % and 71 % in 3PB, and 57 % and 59 % in 4PB. When corrected for shear and indentation deflections, the 3PB PE reduced to 16 % and 14 %, respectively. In 4PB, PE reduced to, 10 % and 7 %, respectively, demonstrating the advantage of the 4PB test configuration over 3PB. The bias resulting from shear deflection was not consistent across deflection measurement methods; and therefore, cannot be generalized with a constant bias correction. The current study highlighted that a slight error in deflection measurement can lead to a significant inaccuracy in EI measurements. This sensitivity comes from the hyperbolic relationship between EI and deflection which not only depends on the ratio of support span to diameter of the specimen but also the test configuration and the ratio of the elastic to shear modulus of specimen. In other words, the PE from neglecting shear effects increases as the specimen EI increases. Accuracy with less than 10 % PE in EI estimations can be achieved by: 1. taking deflection measurements with extensometers, DIC, or FEA; 2. testing in 4PB instead of 3PB; and, 3. correcting for indentation and shear deflections.

Authors

Institutions

Publication Details

Journal
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials
Published
2025-03-30
DOI
https://doi.org/10.1016/j.jmbbm.2025.106986
Primary Topic
Metal Forming Simulation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accurate measurement of a bone surrogate flexural rigidity in three- and four-point bending

Heidi‐Lynn Ploeg, Mahsa Zojaji, Thomas D. Crenshaw, Baixuan Yang et al.
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials
Metal Forming Simulation Techniques
article

Accurate measurement of a bone surrogate flexural rigidity in three- and four-point bending

Heidi‐Lynn Ploeg, Mahsa Zojaji, Thomas D. Crenshaw, Baixuan Yang, Caitlyn J. Collins
article en

Abstract

The mechanical assessment of long bones through bending is an established preclinical approach to evaluate the effectiveness of treatments for osteoporosis and fractures. Three- and four-point bending (3PB and 4PB) tests are the most common methods for mechanical characterization of long bones with Euler-Bernoulli (EB) theory to calculate of bone flexural rigidity (EI). Previous studies demonstrated that EB theory underestimates the EI of long bones due to its reliance on assumptions that are not entirely applicable to long bones. Therefore, the current study aimed to evaluate the factors that affect the percent error (PE) and bias stemming from the omission of contact and shear deflections in the EI estimation using mechanical testing and finite element analysis (FEA). The true EI of a porcine bone surrogate was used to quantify the percent error and bias of EI estimations from three deflection measurement methods and FEA, in 3PB and 4PB. The analysis confirmed that bending was the main component of total deflection, but only contributed to approximately 50 % and 65 % of the total deflection in 3PB and 4PB, respectively. The combined shear and indentation deflections accounted for the remainder of the total deflection. The FEA aligned with 3PB and 4PB tests with less than 10 % deviation. Underestimation of EI was largest with deflection measurements taken from the machine crosshead (PE 74 % in 3PB and 71 % in 4PB). However, these underestimations improved notably when indentation and shear deflections were considered (PE 42 % in 3PB and 39 % in 4PB). The deflection measurements from extensometer and digital image correlation (DIC) underestimated the EI by 66 % and 71 % in 3PB, and 57 % and 59 % in 4PB. When corrected for shear and indentation deflections, the 3PB PE reduced to 16 % and 14 %, respectively. In 4PB, PE reduced to, 10 % and 7 %, respectively, demonstrating the advantage of the 4PB test configuration over 3PB. The bias resulting from shear deflection was not consistent across deflection measurement methods; and therefore, cannot be generalized with a constant bias correction. The current study highlighted that a slight error in deflection measurement can lead to a significant inaccuracy in EI measurements. This sensitivity comes from the hyperbolic relationship between EI and deflection which not only depends on the ratio of support span to diameter of the specimen but also the test configuration and the ratio of the elastic to shear modulus of specimen. In other words, the PE from neglecting shear effects increases as the specimen EI increases. Accuracy with less than 10 % PE in EI estimations can be achieved by: 1. taking deflection measurements with extensometers, DIC, or FEA; 2. testing in 4PB instead of 3PB; and, 3. correcting for indentation and shear deflections.

Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materialsVol. 167
University of Wisconsin–Madison (US), Queen's University (CA), Virginia Tech (US)
Openalex Percentile: Top 94%
Metal Forming Simulation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.