Design and Verification of a Wearable Microcapacitance Test System for POC Biosensing

Nanofarad/picofarad scale ac microcapacitance as an electronic signal has advantages on sensitivity and resolution for high-precision biosensors, while its compact test system for wearable applications has not been commercially available. A precise test system for microcapacitance detection is designed and realized by combining a direct digital synthesizer (DDS) with impedance spectrum method. The system is of high integration, high portability, and low cost and can achieve data transmission with mobile terminals via wireless controlling. It has continuously variable frequency and amplitude modulations of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0\sim 100$ </tex-math></inline-formula> kHz and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0\sim 1.98$ </tex-math></inline-formula> V, respectively. A wide range of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0\sim 100$ </tex-math></inline-formula> nF and a precision as low as 1 pF are realized simultaneously. Combining a sweat collection patch and a capacitive biosensor, this system is employed for hepatitis B surface antibody detection in sweat, with the target concentration in the range from <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$10^{\mathbf {-12}}$ </tex-math></inline-formula> to <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$10^{\mathbf {-16}}$ </tex-math></inline-formula> g/mL and a detection limit of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$5.905\times 10^{\mathbf {-17}}$ </tex-math></inline-formula> g/mL. The application case verifies the system function with high precision, high reliability, stable data communication, as well as excellent field operability. This system provides an executable solution for constructing smart wearable platforms for point-of-care (POC) biosensing based on microcapacitance detection.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3555726
Citations
15
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
11.05

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Verification of a Wearable Microcapacitance Test System for POC Biosensing

Haochen Qi, Hongjie Cheng, Wen Yao, Wenbo Niu et al.
15 citations
IEEE Transactions on Instrumentation and Measurement
Analytical Chemistry and Sensors
11.05
article

Design and Verification of a Wearable Microcapacitance Test System for POC Biosensing

Haochen Qi, Hongjie Cheng, Wen Yao, Wenbo Niu, Jiongming Chen, Zhongxi Yu, Jian Zhang, Jiahao Wang, Jing Huang, Li Lv
article en
15 citations

Abstract

Nanofarad/picofarad scale ac microcapacitance as an electronic signal has advantages on sensitivity and resolution for high-precision biosensors, while its compact test system for wearable applications has not been commercially available. A precise test system for microcapacitance detection is designed and realized by combining a direct digital synthesizer (DDS) with impedance spectrum method. The system is of high integration, high portability, and low cost and can achieve data transmission with mobile terminals via wireless controlling. It has continuously variable frequency and amplitude modulations of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0\sim 100$ </tex-math></inline-formula> kHz and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0\sim 1.98$ </tex-math></inline-formula> V, respectively. A wide range of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0\sim 100$ </tex-math></inline-formula> nF and a precision as low as 1 pF are realized simultaneously. Combining a sweat collection patch and a capacitive biosensor, this system is employed for hepatitis B surface antibody detection in sweat, with the target concentration in the range from <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$10^{\mathbf {-12}}$ </tex-math></inline-formula> to <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$10^{\mathbf {-16}}$ </tex-math></inline-formula> g/mL and a detection limit of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$5.905\times 10^{\mathbf {-17}}$ </tex-math></inline-formula> g/mL. The application case verifies the system function with high precision, high reliability, stable data communication, as well as excellent field operability. This system provides an executable solution for constructing smart wearable platforms for point-of-care (POC) biosensing based on microcapacitance detection.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Wenzhou University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 1%
Analytical Chemistry and Sensors
11.05
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.