RP-CFANet: An Adaptive Photovoltaic Hot-Spot Fault Detection Network Based on Region Perception and Cross-Channel Feature Aggregation

In the process of utilizing thermal infrared sensors to identify photovoltaic (PV) hot-spot faults, due to the diverse shapes of hot-spot faults and environmental interferences, fault characteristics cannot be effectively expressed, which poses a challenge for traditional detection networks in achieving accurate detection. Consequently, an adaptive PV hot-spot fault detection network based on region perception and cross-channel feature aggregation is proposed. First, to reduce the interference of pseudo-highlight features in complex backgrounds, a lite-UNet segmentation network is designed to remove background redundant information and enable the detection network to concentrate on the region of the PV panel. Second, to fully capture the geometric deformations and weak edge characteristics of hot-spot faults, a C2f_DCN module is designed, which enhances the feature extraction capabilities by adaptively adjusting the receptive field. Subsequently, to address the problem of feature coupling often encountered in extracting dense hot-spot fault features, a dense object visual enhancement (DOVE) module is proposed. Through the dynamic aggregation of cross-space features, the feature information of different channels is integrated to improve the detection accuracy of hot-spot faults. Additionally, to further enhance the effective fusion of multiscale features, an adaptive scale converter module (ASCM) detection head is designed. Finally, seven traditional detection methods are chosen for comparison to confirm the benefits of the proposed method. According to the experimental results, the suggested method can detect hot-spot faults with an accuracy of up to 86.5% in complicated inspection environments, which is an increase of 5.6% compared with the basis of the original network.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3555674
Citations
4
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
1.45
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

RP-CFANet: An Adaptive Photovoltaic Hot-Spot Fault Detection Network Based on Region Perception and Cross-Channel Feature Aggregation

Shuai Hao, Xu Ma, Tianrui Qi, Jiahao Li et al.
4 citations
IEEE Transactions on Instrumentation and Measurement
Photovoltaic System Optimization Techniques
1.45
article

RP-CFANet: An Adaptive Photovoltaic Hot-Spot Fault Detection Network Based on Region Perception and Cross-Channel Feature Aggregation

Shuai Hao, Xu Ma, Tianrui Qi, Jiahao Li, Tianqi Li
article en
4 citations

Abstract

In the process of utilizing thermal infrared sensors to identify photovoltaic (PV) hot-spot faults, due to the diverse shapes of hot-spot faults and environmental interferences, fault characteristics cannot be effectively expressed, which poses a challenge for traditional detection networks in achieving accurate detection. Consequently, an adaptive PV hot-spot fault detection network based on region perception and cross-channel feature aggregation is proposed. First, to reduce the interference of pseudo-highlight features in complex backgrounds, a lite-UNet segmentation network is designed to remove background redundant information and enable the detection network to concentrate on the region of the PV panel. Second, to fully capture the geometric deformations and weak edge characteristics of hot-spot faults, a C2f_DCN module is designed, which enhances the feature extraction capabilities by adaptively adjusting the receptive field. Subsequently, to address the problem of feature coupling often encountered in extracting dense hot-spot fault features, a dense object visual enhancement (DOVE) module is proposed. Through the dynamic aggregation of cross-space features, the feature information of different channels is integrated to improve the detection accuracy of hot-spot faults. Additionally, to further enhance the effective fusion of multiscale features, an adaptive scale converter module (ASCM) detection head is designed. Finally, seven traditional detection methods are chosen for comparison to confirm the benefits of the proposed method. According to the experimental results, the suggested method can detect hot-spot faults with an accuracy of up to 86.5% in complicated inspection environments, which is an increase of 5.6% compared with the basis of the original network.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Xi'an University of Science and Technology (CN)
Openalex Percentile: Top 19%
Photovoltaic System Optimization Techniques
1.45
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.