Optical Sensing System Based on Bidirectional Self-Correction Technology: An Online Detection Method for Carbon Disulfide and Sulfur Dioxide in Gas-Insulated Switchgear

Carbon disulfide (CS<sub>2</sub>) and sulfur dioxide (SO<sub>2</sub>) are typical indicative gases for the early warning and diagnosis of faults in gas-insulated switchgear. In this study, an optical sensing system is reported for online detection of CS<sub>2</sub> and SO<sub>2</sub> based on a bidirectional self-correction technology (BSCT). First, the differential absorption signals of CS<sub>2</sub> and SO<sub>2</sub> in the wavelength range of 195-230 nm are obtained using the UV differential optical absorption spectroscopy (UV-DOAS) technique. On this basis, a BSCT is proposed to decouple the spectral lines that exhibit significant overlap. This method primarily employs bidirectional difference spectroscopy to mutually correct the spectra of CS<sub>2</sub> and SO<sub>2</sub>, combined with spectral reconstruction to extract the single-component absorption signals of CS<sub>2</sub> and SO<sub>2</sub> from the mixed gas spectra. Furthermore, the effectiveness of this novel decoupling technique is validated by comparing the decoupling results with the absorption spectra of single-component standard gases at corresponding concentrations. Finally, the quantitative relationships between the concentrations of target gases (CS<sub>2</sub>, SO<sub>2</sub>) and the optical parameters are modeled using the least-squares method. The experimental results show that the mean absolute percentage errors of CS<sub>2</sub> (19.00-3735.35 ppb) and SO<sub>2</sub> (0.19-38.77 ppm) are 0.543 and 0.521%, respectively. At an effective optical range of 50 cm, the system achieves the lowest detection limits of 0.5 ppb for CS<sub>2</sub> and 12 ppb for SO<sub>2</sub>, representing the best results reported to date for the online detection of CS<sub>2</sub> and SO<sub>2</sub> in the ppb-ppm range.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-03-29
DOI
https://doi.org/10.1021/acs.analchem.5c00807
Citations
12
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
9.08
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optical Sensing System Based on Bidirectional Self-Correction Technology: An Online Detection Method for Carbon Disulfide and Sulfur Dioxide in Gas-Insulated Switchgear

Yucun Zhang, Changyin Li, Bingqian Li, Yungang Zhang et al.
12 citations
Analytical Chemistry
Spectroscopy and Laser Applications
9.08
article

Optical Sensing System Based on Bidirectional Self-Correction Technology: An Online Detection Method for Carbon Disulfide and Sulfur Dioxide in Gas-Insulated Switchgear

Yucun Zhang, Changyin Li, Bingqian Li, Yungang Zhang, Jie Gao, Mu Li, Rui Zhu, Fei Xie
article en
12 citations

Abstract

Carbon disulfide (CS<sub>2</sub>) and sulfur dioxide (SO<sub>2</sub>) are typical indicative gases for the early warning and diagnosis of faults in gas-insulated switchgear. In this study, an optical sensing system is reported for online detection of CS<sub>2</sub> and SO<sub>2</sub> based on a bidirectional self-correction technology (BSCT). First, the differential absorption signals of CS<sub>2</sub> and SO<sub>2</sub> in the wavelength range of 195-230 nm are obtained using the UV differential optical absorption spectroscopy (UV-DOAS) technique. On this basis, a BSCT is proposed to decouple the spectral lines that exhibit significant overlap. This method primarily employs bidirectional difference spectroscopy to mutually correct the spectra of CS<sub>2</sub> and SO<sub>2</sub>, combined with spectral reconstruction to extract the single-component absorption signals of CS<sub>2</sub> and SO<sub>2</sub> from the mixed gas spectra. Furthermore, the effectiveness of this novel decoupling technique is validated by comparing the decoupling results with the absorption spectra of single-component standard gases at corresponding concentrations. Finally, the quantitative relationships between the concentrations of target gases (CS<sub>2</sub>, SO<sub>2</sub>) and the optical parameters are modeled using the least-squares method. The experimental results show that the mean absolute percentage errors of CS<sub>2</sub> (19.00-3735.35 ppb) and SO<sub>2</sub> (0.19-38.77 ppm) are 0.543 and 0.521%, respectively. At an effective optical range of 50 cm, the system achieves the lowest detection limits of 0.5 ppb for CS<sub>2</sub> and 12 ppb for SO<sub>2</sub>, representing the best results reported to date for the online detection of CS<sub>2</sub> and SO<sub>2</sub> in the ppb-ppm range.

Analytical ChemistryVol. 97(13)
Yanshan University (CN)
Openalex Percentile: Top 2%
Spectroscopy and Laser Applications
9.08
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.