Local area cooling versus broad area cooling for boil-off reduction in large-scale liquid hydrogen storage tanks

Future use of liquid hydrogen ( ) as an effective energy carrier will require elimination or minimization of hydrogen boil-off that is not utilized by demands in the value chain. The present work promotes local area cooling (LAC) as a promising boil-off reduction technology. In contrast to the more conventional broad area cooling (BAC), LAC targets local, concentrated heat flows e.g. through tank support structures. This yields important practical benefits, especially for large-scale tanks, due to the order-of-magnitude reduction in the size of the cooling system. Such benefits include lower capital costs and simpler installation, maintenance and coolant management. LAC applied outside the outer tank wall is particularly attractive for tanks with evacuated insulation. In a series of numerical studies, we use the finite element method to evaluate the thermal performance of LAC and BAC in the context of ship-borne transport. The studies concern 40 000 m 3 -capacity, skirt-supported tanks insulated using evacuated perlite or helium-filled polyurethane (HePUR) foam. For the perlite-insulated tank, LAC and BAC with liquid nitrogen coolant can reduce the daily boil-off rate from 0.04%/day to, respectively, 0.011%/day and 0.004%/day. The corresponding numbers for CO 2 -based refrigeration are 0.031%/day and 0.028%/day. For the HePUR-insulated tank, which has a higher baseline boil-off rate of 0.24%/day, reduced boil-off rates down to 0.17%/day and 0.04%/day are achievable using LAC and BAC, respectively. LAC and BAC both offer increased power efficiency in comparison to reliquefaction only. • Active cooling solutions for LH 2 storage are quantitatively compared using FEM. • Local area cooling (LAC) / broad area cooling can reduce boiloff by up to 70% / 90%. • LAC is comparatively simple to install & operate, especially for large systems. • Active cooling improves power efficiency in comparison to pure reliquefaction. • Detailed thermal assessment of 40 000 m 3 -capacity, ship-borne hydrogen tanks.

Authors

Institutions

Publication Details

Journal
Cryogenics
Published
2025-03-29
DOI
https://doi.org/10.1016/j.cryogenics.2025.104065
Citations
7
Primary Topic
Spacecraft and Cryogenic Technologies
Type
article
Field-Weighted Citation Impact
34.95
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Local area cooling versus broad area cooling for boil-off reduction in large-scale liquid hydrogen storage tanks

Ailo Aasen, Sindre Stenen Blakseth, Petter Nekså, André Massing
7 citations
Cryogenics
Spacecraft and Cryogenic Technologies
34.95
article

Local area cooling versus broad area cooling for boil-off reduction in large-scale liquid hydrogen storage tanks

Ailo Aasen, Sindre Stenen Blakseth, Petter Nekså, André Massing
article en
7 citations

Abstract

Future use of liquid hydrogen ( ) as an effective energy carrier will require elimination or minimization of hydrogen boil-off that is not utilized by demands in the value chain. The present work promotes local area cooling (LAC) as a promising boil-off reduction technology. In contrast to the more conventional broad area cooling (BAC), LAC targets local, concentrated heat flows e.g. through tank support structures. This yields important practical benefits, especially for large-scale tanks, due to the order-of-magnitude reduction in the size of the cooling system. Such benefits include lower capital costs and simpler installation, maintenance and coolant management. LAC applied outside the outer tank wall is particularly attractive for tanks with evacuated insulation. In a series of numerical studies, we use the finite element method to evaluate the thermal performance of LAC and BAC in the context of ship-borne transport. The studies concern 40 000 m 3 -capacity, skirt-supported tanks insulated using evacuated perlite or helium-filled polyurethane (HePUR) foam. For the perlite-insulated tank, LAC and BAC with liquid nitrogen coolant can reduce the daily boil-off rate from 0.04%/day to, respectively, 0.011%/day and 0.004%/day. The corresponding numbers for CO 2 -based refrigeration are 0.031%/day and 0.028%/day. For the HePUR-insulated tank, which has a higher baseline boil-off rate of 0.24%/day, reduced boil-off rates down to 0.17%/day and 0.04%/day are achievable using LAC and BAC, respectively. LAC and BAC both offer increased power efficiency in comparison to reliquefaction only. • Active cooling solutions for LH 2 storage are quantitatively compared using FEM. • Local area cooling (LAC) / broad area cooling can reduce boiloff by up to 70% / 90%. • LAC is comparatively simple to install & operate, especially for large systems. • Active cooling improves power efficiency in comparison to pure reliquefaction. • Detailed thermal assessment of 40 000 m 3 -capacity, ship-borne hydrogen tanks.

CryogenicsVol. 148
SINTEF (NO), Norwegian University of Science and Technology (NO)
Affordable and clean energy
Openalex Percentile: Top 0%
Spacecraft and Cryogenic Technologies
34.95
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.