Verification of the accuracy of a compact beam energy monitor

A Beam Energy Monitor (BEM) is a novel compact beam diagnostic device for measuring the kinetic energy of charged particle beams of cyclic accelerators. The presented results are based on a BEM developed and tested at the MGC-20 cyclotron of the HUN-REN Institute for Nuclear Research (ATOMKI) in Debrecen, Hungary. In this work the results of the performance tests are reported. After testing the accuracy of the signal processing hardware and software, well-known neutron emission threshold reactions were used to investigate the achievable accuracy of the energy measurement with the new device in real, practical operation.

Authors

Institutions

Publication Details

Journal
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Published
2025-03-30
DOI
https://doi.org/10.1016/j.nima.2025.170483
Citations
1
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
1.88
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Verification of the accuracy of a compact beam energy monitor

L. Csedreki, Z. Kormány
1 citations
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Nuclear Physics and Applications
1.88
article

Verification of the accuracy of a compact beam energy monitor

L. Csedreki, Z. Kormány
article en
1 citations

Abstract

A Beam Energy Monitor (BEM) is a novel compact beam diagnostic device for measuring the kinetic energy of charged particle beams of cyclic accelerators. The presented results are based on a BEM developed and tested at the MGC-20 cyclotron of the HUN-REN Institute for Nuclear Research (ATOMKI) in Debrecen, Hungary. In this work the results of the performance tests are reported. After testing the accuracy of the signal processing hardware and software, well-known neutron emission threshold reactions were used to investigate the achievable accuracy of the energy measurement with the new device in real, practical operation.

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated EquipmentVol. 1076
HUN-REN Institute for Nuclear Research (HU)
Affordable and clean energy
Openalex Percentile: Top 19%
Nuclear Physics and Applications
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Verification of the accuracy of a compact beam energy monitor — L. Csedreki, Z. Kormány · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment (2025) | TGRS Research Map | TGRS