Geometric optimization of a blood pump impeller using the Taguchi method: CFD analysis and experimental evaluation

Rotodynamic Left Ventricular Assist Devices (LVADs) are critical in managing severe heart failure by providing mechanical circulatory support. Improving these blood pumps' efficiency is crucial for both lowering the device's energy consumption and enhancing patient comfort. In this study, the efficiency of a reference centrifugal blood pump was improved through geometric optimization and validated using computational fluid dynamics (CFD) simulations and experiments. The number of blades, inlet width, outlet width, inlet angle, and outlet angle are among the important impeller parameters that were optimized at three different levels. The orthogonal array of the Taguchi design method was used to reduce the 243 possible configurations from the full-factorial experimental design to 27 trial tests. Analysis of Variance (ANOVA) was used to determine the optimal geometric parameters, which led to maximum efficiency after S/N ratios were analyzed using MINITAB-18 software. The performance of the optimized pump was evaluated via CFD at 3300, 3150, and 3450 pump rotation speeds, resulting in a 21% increase in hydraulic efficiency at the design point (5 ​L/min, 3300 ​rpm, and 128.515 ​mm-Hg). Furthermore, experimental results demonstrated reduced power consumption for the optimized pump compared to the reference pump. This study highlights the potential of geometric optimization in advancing the performance of rotodynamic LVADs. • Applied a geometric optimization based on the Taguchi method for a centrifugal blood pump. • Achieved improvements in efficiency, wall shear stress and pressure head compared to the reference pump. • Carried out computational fluid dynamics simulations of the blood pump and validated the results of it with experiments. • Optimized the impeller number, inlet/outlet width, and angles of a blood pump to improve hydraulic performance.

Authors

Institutions

Publication Details

Journal
Medicine in Novel Technology and Devices
Published
2025-03-29
DOI
https://doi.org/10.1016/j.medntd.2025.100364
Citations
2
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Geometric optimization of a blood pump impeller using the Taguchi method: CFD analysis and experimental evaluation

A. Diallo, Rafet Yapıcı, Ömer İncebay, Hasan Çınar
2 citations
Medicine in Novel Technology and Devices
Mechanical Circulatory Support Devices
1.35
article

Geometric optimization of a blood pump impeller using the Taguchi method: CFD analysis and experimental evaluation

A. Diallo, Rafet Yapıcı, Ömer İncebay, Hasan Çınar
article en
2 citations

Abstract

Rotodynamic Left Ventricular Assist Devices (LVADs) are critical in managing severe heart failure by providing mechanical circulatory support. Improving these blood pumps' efficiency is crucial for both lowering the device's energy consumption and enhancing patient comfort. In this study, the efficiency of a reference centrifugal blood pump was improved through geometric optimization and validated using computational fluid dynamics (CFD) simulations and experiments. The number of blades, inlet width, outlet width, inlet angle, and outlet angle are among the important impeller parameters that were optimized at three different levels. The orthogonal array of the Taguchi design method was used to reduce the 243 possible configurations from the full-factorial experimental design to 27 trial tests. Analysis of Variance (ANOVA) was used to determine the optimal geometric parameters, which led to maximum efficiency after S/N ratios were analyzed using MINITAB-18 software. The performance of the optimized pump was evaluated via CFD at 3300, 3150, and 3450 pump rotation speeds, resulting in a 21% increase in hydraulic efficiency at the design point (5 ​L/min, 3300 ​rpm, and 128.515 ​mm-Hg). Furthermore, experimental results demonstrated reduced power consumption for the optimized pump compared to the reference pump. This study highlights the potential of geometric optimization in advancing the performance of rotodynamic LVADs. • Applied a geometric optimization based on the Taguchi method for a centrifugal blood pump. • Achieved improvements in efficiency, wall shear stress and pressure head compared to the reference pump. • Carried out computational fluid dynamics simulations of the blood pump and validated the results of it with experiments. • Optimized the impeller number, inlet/outlet width, and angles of a blood pump to improve hydraulic performance.

Medicine in Novel Technology and DevicesVol. 26
Necmettin Erbakan University (TR), Konya Technical University (TR)
Openalex Percentile: Top 21%
Mechanical Circulatory Support Devices
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.