Diffusion principles of SF6 tracer gas: constraints on SF6 mixing distance in mine tunnels

Mine wind measurement work is an important task to ensure the normal operation of mine production and environmental safety. The traditional wind measurement method uses the average wind speed and average cross-sectional area of the tunnel to calculate the air volume. Due to the fact that the tracer gas wind measurement method does not require the measurement of average wind speed and tunnel cross-sectional area, the error is smaller than traditional wind measurement methods. The wind measurement method monitors SF<sub>6</sub> diffusion by stably releasing SF<sub>6</sub> in the tunnel, and then measuring the SF<sub>6</sub> concentration until achieving even distribution. The accuracy of SF<sub>6</sub> concentration measurement directly determines the accuracy of wind measurement. The premise of accurately measuring the uniform concentration of SF<sub>6</sub> distribution is to determine the SF<sub>6</sub> mixing distance. This study analyzes the diffusion principles of SF<sub>6</sub> in the tunnel, and applies the computational fluid dynamics method for three intersecting tunnels to study the SF<sub>6</sub>-air mixing distance in the intersection tunnel under a range of conditions to assess the effects of various parameters on the SF<sub>6</sub> mixing distance. The SF<sub>6</sub> concentration distribution was investigated to determine the optimal location for concentration sensors. The results indicate that the SF<sub>6</sub> mixing distance increases with gravity, while the SF<sub>6</sub> concentration distribution rectangular and semi-circular arch tunnels follows a relationship of left and right interchangeability. For a given cross-sectional shape, shorter mixing distances are associated with larger tunnel cross-sectional areas, lower SF<sub>6</sub> concentrations, higher tunnel wind speeds, and greater angles between the two air inlet tunnels. The results of this study provide a reference for selecting appropriate numerical simulation models for more accurate mine wind measurement work and future intelligent ventilation wind measurement.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-03-29
DOI
https://doi.org/10.1038/s41598-025-86864-5
Citations
3
Primary Topic
Vacuum and Plasma Arcs
Type
article
Field-Weighted Citation Impact
3.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diffusion principles of SF6 tracer gas: constraints on SF6 mixing distance in mine tunnels

Xue Liu, Jian Liu, Dong Wang, Fang Xu
3 citations
Scientific Reports
Vacuum and Plasma Arcs
3.74
article

Diffusion principles of SF6 tracer gas: constraints on SF6 mixing distance in mine tunnels

Xue Liu, Jian Liu, Dong Wang, Fang Xu
article en
3 citations

Abstract

Mine wind measurement work is an important task to ensure the normal operation of mine production and environmental safety. The traditional wind measurement method uses the average wind speed and average cross-sectional area of the tunnel to calculate the air volume. Due to the fact that the tracer gas wind measurement method does not require the measurement of average wind speed and tunnel cross-sectional area, the error is smaller than traditional wind measurement methods. The wind measurement method monitors SF<sub>6</sub> diffusion by stably releasing SF<sub>6</sub> in the tunnel, and then measuring the SF<sub>6</sub> concentration until achieving even distribution. The accuracy of SF<sub>6</sub> concentration measurement directly determines the accuracy of wind measurement. The premise of accurately measuring the uniform concentration of SF<sub>6</sub> distribution is to determine the SF<sub>6</sub> mixing distance. This study analyzes the diffusion principles of SF<sub>6</sub> in the tunnel, and applies the computational fluid dynamics method for three intersecting tunnels to study the SF<sub>6</sub>-air mixing distance in the intersection tunnel under a range of conditions to assess the effects of various parameters on the SF<sub>6</sub> mixing distance. The SF<sub>6</sub> concentration distribution was investigated to determine the optimal location for concentration sensors. The results indicate that the SF<sub>6</sub> mixing distance increases with gravity, while the SF<sub>6</sub> concentration distribution rectangular and semi-circular arch tunnels follows a relationship of left and right interchangeability. For a given cross-sectional shape, shorter mixing distances are associated with larger tunnel cross-sectional areas, lower SF<sub>6</sub> concentrations, higher tunnel wind speeds, and greater angles between the two air inlet tunnels. The results of this study provide a reference for selecting appropriate numerical simulation models for more accurate mine wind measurement work and future intelligent ventilation wind measurement.

Scientific ReportsVol. 15(1)
Liaoning Technical University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 8%
Vacuum and Plasma Arcs
3.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.