Scalable ion concentration polarization dialyzer for peritoneal dialysate regeneration

A wearable artificial kidney (WAK) stands poised to offer dialysis treatment with maximal temporal and spatial flexibility for end-stage renal disease (ESRD) patients, while portability has not yet been achieved due to difficulties in portable purification. The ion concentration polarization (ICP), one of the nanoelectrokinetic phenomenon, has garnered substantial attention in the realm of portable purification applications, owing to its remarkable capacity for charge separation. In this work, scalable ICP dialyzer with 10,000-fold increase in throughput, was applied for peritoneal dialysate regeneration. First, the mechanism underpinning dialysate purification was corroborated based on micro-nanofluidics. Simultaneously, the electrochemical reactions utilized the complete decomposition of uncharged toxin (urea), achieving approximately 99% clearance, while the ICP phenomenon promoted the removal of positively charged toxin (creatinine), achieving approximately 30% clearance. Second, 3-D scalable ICP dialyzer was developed with a creation of micro-nanofluidic environment inside. Throughput scalability was demonstrated up to 1 mL/min with average approximately 30% toxins clearance. Ultimately, the 3-D ICP dialyzer was applied to assist peritoneal dialysis (PD) using a bilateral nephrectomy rat model. We demonstrated that regenerated dialysate successfully reduced in vivo toxicity, with average toxins removal ratio of approximately 30% per cycle. We believe that the integration of this scalable ICP dialyzer into the WAK holds tremendous potential for substantially enhancing the quality of life for individuals with ESRD.

Authors

Institutions

Publication Details

Journal
Journal of Nanobiotechnology
Published
2025-03-29
DOI
https://doi.org/10.1186/s12951-025-03294-1
Primary Topic
Dialysis and Renal Disease Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Scalable ion concentration polarization dialyzer for peritoneal dialysate regeneration

Jung Chan Lee, Wan‐Seob Cho, Seongjun Hong, Kihong Kim et al.
Journal of Nanobiotechnology
Dialysis and Renal Disease Management
article

Scalable ion concentration polarization dialyzer for peritoneal dialysate regeneration

Jung Chan Lee, Wan‐Seob Cho, Seongjun Hong, Kihong Kim, Dong Ah Shin, Seung Hee Yang, Hajeong Lee, Dong Ki Kim, Gun Yong Sung, Hee Chan Kim, Won‐Seok Kim, Kyung‐Hee Kim, Jeongeun Lee, Kyoung Jin Lee, Sung Jae Kim, Yon Su Kim, Sunhwa Lee
article en

Abstract

A wearable artificial kidney (WAK) stands poised to offer dialysis treatment with maximal temporal and spatial flexibility for end-stage renal disease (ESRD) patients, while portability has not yet been achieved due to difficulties in portable purification. The ion concentration polarization (ICP), one of the nanoelectrokinetic phenomenon, has garnered substantial attention in the realm of portable purification applications, owing to its remarkable capacity for charge separation. In this work, scalable ICP dialyzer with 10,000-fold increase in throughput, was applied for peritoneal dialysate regeneration. First, the mechanism underpinning dialysate purification was corroborated based on micro-nanofluidics. Simultaneously, the electrochemical reactions utilized the complete decomposition of uncharged toxin (urea), achieving approximately 99% clearance, while the ICP phenomenon promoted the removal of positively charged toxin (creatinine), achieving approximately 30% clearance. Second, 3-D scalable ICP dialyzer was developed with a creation of micro-nanofluidic environment inside. Throughput scalability was demonstrated up to 1 mL/min with average approximately 30% toxins clearance. Ultimately, the 3-D ICP dialyzer was applied to assist peritoneal dialysis (PD) using a bilateral nephrectomy rat model. We demonstrated that regenerated dialysate successfully reduced in vivo toxicity, with average toxins removal ratio of approximately 30% per cycle. We believe that the integration of this scalable ICP dialyzer into the WAK holds tremendous potential for substantially enhancing the quality of life for individuals with ESRD.

Journal of NanobiotechnologyVol. 23(1)
Seoul National University (KR), Hallym University (KR), Seoul National University Hospital (KR), Kangwon National University Hospital (KR), CHA University (KR)
Ministry of Science and ICT, South Korea
Openalex Percentile: Top 92%
Dialysis and Renal Disease Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.