[Accuracy of segmented rotational motion-based osteotomy module for dental implant robot in anterior immediate implantation: an <i>in vitro</i> study].

<b>Objective:</b> To preliminarily evaluate the accuracy of a segmented rotational motion-based osteotomy module for autonomous dental implant robots in immediate implant placement in the anterior region through an <i>in vitro</i> model experiment, providing references for clinical practice. <b>Methods:</b> Twenty-three identical commercial maxillary resin models with dentition defects for immediate implant placement were divided into three groups: a fully guided static computer-assisted implant surgery (sCAIS) group (<i>n</i>=5), a robotic computer-assisted implant surgery (rCAIS) group based on conventional coronal-apical linear motion osteotomy (rCAIS-C, <i>n</i>=9) and a rCAIS group based on segmented rotational motion osteotomy (rCAIS-S, <i>n</i>=9). Two implants were placed in each model using the corresponding surgical protocols. Intraoral scan data of pre-and post-operative models were imported into software to evaluate deviations between the actual and planned implant positions. <b>Results:</b> In the rCAIS-S group, the global deviations at the implant platform and apex were 0.50 (0.32) mm and 0.52 (0.22) mm, respectively, with an angular deviation of 1.08° (0.49°). These values were significantly smaller than those in the sCAIS group [platform: 0.88 (0.50) mm, apex: 1.44 (0.50) mm, angular deviation: 2.86° (1.76°), <i>P</i><0.05]. rCAIS-S group also showed significantly smaller platform and apex deviations compared to rCAIS-C group [platform: 0.69 (0.12) mm, apex: 0.94 (0.16) mm, <i>P</i><0.05], though angular deviations of rCAIS-S group did not differ significantly from rCAIS-C group [1.27° (0.56°), <i>P</i>>0.05]. <b>Conclusions:</b> Within the limitation of this study, the segmented rotational motion-based osteotomy module for dental implant robots demonstrates superior accuracy in immediate implant placement in the anterior area compared to sCAIS and rCAIS based on conventional coronal-apical linear motion osteotomy.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2025-03-28
DOI
https://doi.org/10.3760/cma.j.cn112144-20250120-00027
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

[Accuracy of segmented rotational motion-based osteotomy module for dental implant robot in anterior immediate implantation: an in vitro study].

Fan Liu, M.-Z. Wang, Rui Xie, Yong S. Chu et al.
PubMed
Dental Implant Techniques and Outcomes
article

[Accuracy of segmented rotational motion-based osteotomy module for dental implant robot in anterior immediate implantation: an in vitro study].

Fan Liu, M.-Z. Wang, Rui Xie, Yong S. Chu, Jiaheng Wei
article en

Abstract

<b>Objective:</b> To preliminarily evaluate the accuracy of a segmented rotational motion-based osteotomy module for autonomous dental implant robots in immediate implant placement in the anterior region through an <i>in vitro</i> model experiment, providing references for clinical practice. <b>Methods:</b> Twenty-three identical commercial maxillary resin models with dentition defects for immediate implant placement were divided into three groups: a fully guided static computer-assisted implant surgery (sCAIS) group (<i>n</i>=5), a robotic computer-assisted implant surgery (rCAIS) group based on conventional coronal-apical linear motion osteotomy (rCAIS-C, <i>n</i>=9) and a rCAIS group based on segmented rotational motion osteotomy (rCAIS-S, <i>n</i>=9). Two implants were placed in each model using the corresponding surgical protocols. Intraoral scan data of pre-and post-operative models were imported into software to evaluate deviations between the actual and planned implant positions. <b>Results:</b> In the rCAIS-S group, the global deviations at the implant platform and apex were 0.50 (0.32) mm and 0.52 (0.22) mm, respectively, with an angular deviation of 1.08° (0.49°). These values were significantly smaller than those in the sCAIS group [platform: 0.88 (0.50) mm, apex: 1.44 (0.50) mm, angular deviation: 2.86° (1.76°), <i>P</i><0.05]. rCAIS-S group also showed significantly smaller platform and apex deviations compared to rCAIS-C group [platform: 0.69 (0.12) mm, apex: 0.94 (0.16) mm, <i>P</i><0.05], though angular deviations of rCAIS-S group did not differ significantly from rCAIS-C group [1.27° (0.56°), <i>P</i>>0.05]. <b>Conclusions:</b> Within the limitation of this study, the segmented rotational motion-based osteotomy module for dental implant robots demonstrates superior accuracy in immediate implant placement in the anterior area compared to sCAIS and rCAIS based on conventional coronal-apical linear motion osteotomy.

PubMedVol. 60(4)
National Clinical Research Center for Digestive Diseases (CN), National Clinical Research (US), Stomatology Hospital (CN), Air Force Medical University (CN)
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.