[Application of left ventricular assist device in the treatment of end-stage heart failure:a multi-center report of 48 cases].

<b>Objective:</b> To evaluate the clinical efficacy of left ventricular assist device(LVAD) in the treatment of end-stage heart failure. <b>Methods:</b> This is a retrospective case series study. Data were retrospectively analyzed from 48 patients treated at eight domestic cardiac surgery centers in China between March 2022 and September 2024, who underwent LVAD implantation due to end-stage heart failure. All surgeries were led by the cardiovascular surgery team from Nanjing First Hospital. The study included 42 male and 6 female patients, aged (59.1±12.3) years (range:28 to 73 years). All patients had a preoperative New York Heart Association(NYHA) functional class of Ⅳ. General preoperative data, intraoperative extracorporeal circulation time, cross-clamp time, postoperative ICU stay, hospital stay, pump parameters at discharge, intraoperative and postoperative left ventricular end-diastolic diameter, left ventricular ejection fraction, and follow-up results post-discharge were collected. The generalized estimation equation was used to compare the difference of cardiac function indexes in patients with different follow-up time points. The Tukey's Honestly Significant Difference test was used for pairwise comparison within the group. <b>Results:</b> The surgery was successfully completed for 47 patients, and 1 perioperative death. The extracorporeal circulation time was (122.4±21.6) minutes (range: 101 to 200 minutes), the cross-clamp time was (70.1±18.3) minutes (range: 101 to 200 minutes), the postoperative ICU length of stay was (6.9±3.2) days (range: 2 to 23 days), and the hospital length of stay was (28.1±4.2) days (range: 23 to 42 days). At discharge, the blood bump flow rate was (3.4±0.6) L/min(range: 3.1 to 3.6 L/min), and speed was (2 791.3±142.0) r/min(range: 2 680 to 3 250 r/min). The follow-up period was (12.2±0.78) months (range:2 to 24 months) of 47 patients. One case underwent heart transplantation during the follow-up period, and 3 cases died, with no major device malfunction events. Three months post-surgery, the patients showed a significant reduction in left ventricular end-diastolic diameter compared to pre-surgery ((69.1±8.3) mm <i>vs.</i> (77.3±8.3) mm, <i>q</i>=6.73, <i>P</i><0.01); the left ventricular ejection fraction significantly increased ((29.6±8.0)% <i>vs.</i> (23.2±5.8)%, <i>q</i>=6.49, <i>P</i><0.01); and the 6-minute walk distance significantly improved ((382.0±12.8)metres <i>vs.</i> (114.8±18.4)metres, <i>q</i>=116.56, <i>P</i><0.01). Six months postoperatively, all patients' cardiac function had recovered to NYHA class Ⅰor Ⅱ. <b>Conclusions:</b> Preliminary research findings indicate that left ventricular assist device therapy yields favorable outcomes in the treatment of end-stage heart failure. serving as a bridge to transplantation, recovery, or a destination therapy.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2025-05-01
DOI
https://doi.org/10.3760/cma.j.cn112139-20241204-00548
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

[Application of left ventricular assist device in the treatment of end-stage heart failure:a multi-center report of 48 cases].

Huanjun Ding, Jou‐Kou Wang, Xuhong Cao, Ruojun Wang et al.
PubMed
Mechanical Circulatory Support Devices
article

[Application of left ventricular assist device in the treatment of end-stage heart failure:a multi-center report of 48 cases].

Huanjun Ding, Jou‐Kou Wang, Xuhong Cao, Ruojun Wang, Qiulian Zhou, Hao Jiang
article en

Abstract

<b>Objective:</b> To evaluate the clinical efficacy of left ventricular assist device(LVAD) in the treatment of end-stage heart failure. <b>Methods:</b> This is a retrospective case series study. Data were retrospectively analyzed from 48 patients treated at eight domestic cardiac surgery centers in China between March 2022 and September 2024, who underwent LVAD implantation due to end-stage heart failure. All surgeries were led by the cardiovascular surgery team from Nanjing First Hospital. The study included 42 male and 6 female patients, aged (59.1±12.3) years (range:28 to 73 years). All patients had a preoperative New York Heart Association(NYHA) functional class of Ⅳ. General preoperative data, intraoperative extracorporeal circulation time, cross-clamp time, postoperative ICU stay, hospital stay, pump parameters at discharge, intraoperative and postoperative left ventricular end-diastolic diameter, left ventricular ejection fraction, and follow-up results post-discharge were collected. The generalized estimation equation was used to compare the difference of cardiac function indexes in patients with different follow-up time points. The Tukey's Honestly Significant Difference test was used for pairwise comparison within the group. <b>Results:</b> The surgery was successfully completed for 47 patients, and 1 perioperative death. The extracorporeal circulation time was (122.4±21.6) minutes (range: 101 to 200 minutes), the cross-clamp time was (70.1±18.3) minutes (range: 101 to 200 minutes), the postoperative ICU length of stay was (6.9±3.2) days (range: 2 to 23 days), and the hospital length of stay was (28.1±4.2) days (range: 23 to 42 days). At discharge, the blood bump flow rate was (3.4±0.6) L/min(range: 3.1 to 3.6 L/min), and speed was (2 791.3±142.0) r/min(range: 2 680 to 3 250 r/min). The follow-up period was (12.2±0.78) months (range:2 to 24 months) of 47 patients. One case underwent heart transplantation during the follow-up period, and 3 cases died, with no major device malfunction events. Three months post-surgery, the patients showed a significant reduction in left ventricular end-diastolic diameter compared to pre-surgery ((69.1±8.3) mm <i>vs.</i> (77.3±8.3) mm, <i>q</i>=6.73, <i>P</i><0.01); the left ventricular ejection fraction significantly increased ((29.6±8.0)% <i>vs.</i> (23.2±5.8)%, <i>q</i>=6.49, <i>P</i><0.01); and the 6-minute walk distance significantly improved ((382.0±12.8)metres <i>vs.</i> (114.8±18.4)metres, <i>q</i>=116.56, <i>P</i><0.01). Six months postoperatively, all patients' cardiac function had recovered to NYHA class Ⅰor Ⅱ. <b>Conclusions:</b> Preliminary research findings indicate that left ventricular assist device therapy yields favorable outcomes in the treatment of end-stage heart failure. serving as a bridge to transplantation, recovery, or a destination therapy.

PubMedVol. 63(5)
Xuzhou Medical College (CN), Huaian First People’s Hospital (CN), Second People’s Hospital of Huai’an (CN), Nanjing Medical University (CN)
Openalex Percentile: Top 94%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.