Development of Coumarin‐Based Probe for Spectrofluorometric Lead Determination in the Human Plasma: Exploring an Association With Otitis Media

Chronic otitis media poses a significant global health challenge, particularly burdening low socioeconomic areas, notably in developing nations. Despite its prevalence, the role of lead in chronic otitis media remains largely overlooked. This study introduces an innovative spectrofluorometric technique for highly sensitive lead detection in human plasma samples at the nano-level. The method capitalizes on the interaction between lead ions and 7,8-dihydroxy-4-phenylcoumarin, generating a distinct fluorescent product. This complex exhibit modified fluorescence characteristics compared to free 7,8-dihydroxy-4-phenylcoumarin, emitting at 505 nm when excited at 330 nm. This shift, accompanied by an increase in fluorescence intensity, enables precise lead quantification even within complex plasma matrices. Validation confirmed a consistent linear relationship within the 200-4000 ng/mL range. Application of the validated method revealed elevated lead levels in plasma samples from chronic otitis media patients compared to healthy controls. These findings suggest a potential link between lead exposure and chronic otitis media development, though further research is warranted for confirmation. This research underscores the importance of considering lead's impact on chronic otitis media etiology and progression, especially in vulnerable populations.

Authors

Institutions

Publication Details

Journal
Luminescence
Published
2025-03-27
DOI
https://doi.org/10.1002/bio.70155
Primary Topic
Ear Surgery and Otitis Media
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of Coumarin‐Based Probe for Spectrofluorometric Lead Determination in the Human Plasma: Exploring an Association With Otitis Media

Mahmoud E. Alsobky, Mohamed S. Imam, Amal M. Aladwani, Rahaf M. Aladwani et al.
Luminescence
Ear Surgery and Otitis Media
article

Development of Coumarin‐Based Probe for Spectrofluorometric Lead Determination in the Human Plasma: Exploring an Association With Otitis Media

Mahmoud E. Alsobky, Mohamed S. Imam, Amal M. Aladwani, Rahaf M. Aladwani, Jasmine N. A. Albukhari, Abrar A. Omayrah, Jenaan A. S. Alshahrani, Joud M. A. Alamri, Ghuyum S. A. Al Zamil, Danah M. Alahmri, Reuof A. N. Alotaibi
article en

Abstract

Chronic otitis media poses a significant global health challenge, particularly burdening low socioeconomic areas, notably in developing nations. Despite its prevalence, the role of lead in chronic otitis media remains largely overlooked. This study introduces an innovative spectrofluorometric technique for highly sensitive lead detection in human plasma samples at the nano-level. The method capitalizes on the interaction between lead ions and 7,8-dihydroxy-4-phenylcoumarin, generating a distinct fluorescent product. This complex exhibit modified fluorescence characteristics compared to free 7,8-dihydroxy-4-phenylcoumarin, emitting at 505 nm when excited at 330 nm. This shift, accompanied by an increase in fluorescence intensity, enables precise lead quantification even within complex plasma matrices. Validation confirmed a consistent linear relationship within the 200-4000 ng/mL range. Application of the validated method revealed elevated lead levels in plasma samples from chronic otitis media patients compared to healthy controls. These findings suggest a potential link between lead exposure and chronic otitis media development, though further research is warranted for confirmation. This research underscores the importance of considering lead's impact on chronic otitis media etiology and progression, especially in vulnerable populations.

LuminescenceVol. 40(4)
Cairo University (EG), Taif University (SA), Al-Azhar University (EG), Najran University (SA)
Partnerships for the goals
Openalex Percentile: Top 92%
Ear Surgery and Otitis Media
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development of Coumarin‐Based Probe for Spectrofluorometric Lead Determination in the Human Plasma: Exploring an Association With Otitis Media — Mahmoud E. Alsobky, Mohamed S. Imam, et al. · Luminescence (2025) | TGRS Research Map | TGRS