Disopyramide Bioanalytical Method Development Ad Validation in Rabbit Plasma Using RP-UPLC Following ICH M10 Guidelines

A simple, Accurate, precise method was developed for the estimation of Disopyramide in rabbit plasma was developed and validated. By using precipitation method, the sample preparation was prepared. Chromatogram was run through Std Hibar C18 (100 x 2.1 mm, 2m) Mobile phase containing Buffer Ammonium Acetate:  Methanol taken in the ratio 60:40 was pumped through column at a flow rate of 0.2ml/min. For the separation of Disopyramide, Internal Standard [IS] used was Darunavir. The Temperature was maintained at 30°C. Optimized wavelength selected was 215nm.  Retention time of Disopyramide and Internal Standard were found to be 1.281 min and 1.535 min. The standard curve was linear (R2 >0.995) over the concentration range of 0.15-6 ng/ml. All the analytical validation parameters were determined as per ICH guidelines The bioanalytical method developed approach was selective, robust, and reliable, as accuracy, precision, recovery, and other validation parameters were all within the recommendation’s limitations. 

Authors

Publication Details

Journal
African Journal of Biomedical Research
Published
2024-11-24
DOI
https://doi.org/10.53555/ajbr.v27i4s.7238
Primary Topic
Protein purification and stability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Disopyramide Bioanalytical Method Development Ad Validation in Rabbit Plasma Using RP-UPLC Following ICH M10 Guidelines

Tanniru Rajeswari
African Journal of Biomedical Research
Protein purification and stability
article

Disopyramide Bioanalytical Method Development Ad Validation in Rabbit Plasma Using RP-UPLC Following ICH M10 Guidelines

Tanniru Rajeswari
article en

Abstract

A simple, Accurate, precise method was developed for the estimation of Disopyramide in rabbit plasma was developed and validated. By using precipitation method, the sample preparation was prepared. Chromatogram was run through Std Hibar C18 (100 x 2.1 mm, 2m) Mobile phase containing Buffer Ammonium Acetate:  Methanol taken in the ratio 60:40 was pumped through column at a flow rate of 0.2ml/min. For the separation of Disopyramide, Internal Standard [IS] used was Darunavir. The Temperature was maintained at 30°C. Optimized wavelength selected was 215nm.  Retention time of Disopyramide and Internal Standard were found to be 1.281 min and 1.535 min. The standard curve was linear (R2 >0.995) over the concentration range of 0.15-6 ng/ml. All the analytical validation parameters were determined as per ICH guidelines The bioanalytical method developed approach was selective, robust, and reliable, as accuracy, precision, recovery, and other validation parameters were all within the recommendation’s limitations. 

African Journal of Biomedical Research
Zero hunger
Openalex Percentile: Top 77%
Protein purification and stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.