Simultaneous rp-hplc method development and validation of bilastine and montelukast in bulk

A rapid and precise reverse phase high performance liquid chromatographic method has been developed for the validated of Montelukast and Bilastine, in its pure form as well as in tablet dosage form. Chromatography was carried out on a Zorbax C18 (4.6 x 150mm, 5µm) column using a mixture of Methanol: Phosphate Buffer pH 3.9 (55:45v/v) as the mobile phase at a flow rate of 1.0ml/min, the detection was carried out at 255nm. The retention time of the Montelukast and Bilastine was 2.061, 2.462 ±0.02min respectively. The method produce linear responses in the concentration range of 1-5µg/ml of Montelukast and 100-500µg/ml of Bilastine. The method precision for the determination of assay was below 2.0%RSD. The method is useful in the quality control of bulk and pharmaceutical formulations.

Authors

Institutions

Publication Details

Journal
International Journal of Pharmaceuticals and Health Care Research
Published
2024-11-24
DOI
https://doi.org/10.61096/ijphr.v12.iss4.2024.412-420
Primary Topic
Nanoparticle-Based Drug Delivery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous rp-hplc method development and validation of bilastine and montelukast in bulk

Tianzhi Rao, Cheepurupalli Prasad, Mavuri Ramyasri Bramaramba
International Journal of Pharmaceuticals and Health Care Research
Nanoparticle-Based Drug Delivery
article

Simultaneous rp-hplc method development and validation of bilastine and montelukast in bulk

Tianzhi Rao, Cheepurupalli Prasad, Mavuri Ramyasri Bramaramba
article en

Abstract

A rapid and precise reverse phase high performance liquid chromatographic method has been developed for the validated of Montelukast and Bilastine, in its pure form as well as in tablet dosage form. Chromatography was carried out on a Zorbax C18 (4.6 x 150mm, 5µm) column using a mixture of Methanol: Phosphate Buffer pH 3.9 (55:45v/v) as the mobile phase at a flow rate of 1.0ml/min, the detection was carried out at 255nm. The retention time of the Montelukast and Bilastine was 2.061, 2.462 ±0.02min respectively. The method produce linear responses in the concentration range of 1-5µg/ml of Montelukast and 100-500µg/ml of Bilastine. The method precision for the determination of assay was below 2.0%RSD. The method is useful in the quality control of bulk and pharmaceutical formulations.

International Journal of Pharmaceuticals and Health Care ResearchVol. 12(4)
Andhra University (IN)
Openalex Percentile: Top 87%
Nanoparticle-Based Drug Delivery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.