Automatic bi-atrial segmentation and biomarker extraction from late gadolinium-enhanced MRI using deep learning

Atrial fibrillation (AF) is associated with progressive structural remodeling of the atria, including chamber dilation, fibrosis, and variations in atrial wall thickness (AWT). Late gadolinium-enhanced (LGE) magnetic resonance imaging (MRI) has been used to quantify left atrium (LA) fibrosis for guiding adjunctive ablation beyond pulmonary vein isolation, though results have varied. A major limitation is the lack of a robust segmentation method for accurately assessing both atrial anatomy and fibrosis, coupled with the exclusion of the right atrium (RA) in the analysis. This study introduces biAtriaNet, a deep learning pipeline developed to automate segmentation of both LA and RA and to evaluate atrial fibrosis, AWT, and chamber diameter and volume from LGE-MRIs to support targeted AF ablation. biAtriaNet was trained and validated on 2D cine-MRIs from 4860 UK Biobank participants and 3D LGE-MRIs from 60 AF patients from the University of Utah, with independent testing on 11 3D LGE-MRIs at Waikato Hospital, New Zealand. The biAtriaNet consists of two CNNs based on a modified U-Net architecture with residual connections and batch normalization, optimized based on prior global benchmark study. This approach achieved accurate, consistent segmentation and biomarker extraction in UK Biobank and Utah datasets, validated against expert annotations. Additionally, biAtriaNet showed high transferability to independent datasets, achieving Dice scores of 91.1% for LA and 88.6% for RA. Chamber volume estimates closely matched ground truth values (LA: 89.8 ± 33.0 ml versus 91.1 ± 41.2 ml; RA: 70.8 ± 16.9 ml versus 72.3 ± 20.5 ml) with >90% accuracy in chamber measurements. AWT accuracies were 95.9% for LA and 94.6% for RA, while fibrosis estimates showed Kolmogorov-Smirnov correlations of 86.3% (LA) and 90.6% (RA) (p < 0.05). By enabling robust bi-atrial segmentation and biomarker extraction from LGE-MRIs, biAtriaNet has the potential to enhance patient-specific AF treatment strategies.

Authors

Institutions

Publication Details

Journal
Expert Systems with Applications
Published
2025-03-29
DOI
https://doi.org/10.1016/j.eswa.2025.127335
Citations
1
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automatic bi-atrial segmentation and biomarker extraction from late gadolinium-enhanced MRI using deep learning

Martin K. Stiles, James J. Kennelly, Vadim V. Fedorov, Jichao Zhao et al.
1 citations
Expert Systems with Applications
Cardiac Imaging and Diagnostics
1.36
article

Automatic bi-atrial segmentation and biomarker extraction from late gadolinium-enhanced MRI using deep learning

Martin K. Stiles, James J. Kennelly, Vadim V. Fedorov, Jichao Zhao, Zhaohan Xiong, Roshan Sharma, Steffen Erhard Petersen, Aaqel Nalar, Fan Feng
article en
1 citations

Abstract

Atrial fibrillation (AF) is associated with progressive structural remodeling of the atria, including chamber dilation, fibrosis, and variations in atrial wall thickness (AWT). Late gadolinium-enhanced (LGE) magnetic resonance imaging (MRI) has been used to quantify left atrium (LA) fibrosis for guiding adjunctive ablation beyond pulmonary vein isolation, though results have varied. A major limitation is the lack of a robust segmentation method for accurately assessing both atrial anatomy and fibrosis, coupled with the exclusion of the right atrium (RA) in the analysis. This study introduces biAtriaNet, a deep learning pipeline developed to automate segmentation of both LA and RA and to evaluate atrial fibrosis, AWT, and chamber diameter and volume from LGE-MRIs to support targeted AF ablation. biAtriaNet was trained and validated on 2D cine-MRIs from 4860 UK Biobank participants and 3D LGE-MRIs from 60 AF patients from the University of Utah, with independent testing on 11 3D LGE-MRIs at Waikato Hospital, New Zealand. The biAtriaNet consists of two CNNs based on a modified U-Net architecture with residual connections and batch normalization, optimized based on prior global benchmark study. This approach achieved accurate, consistent segmentation and biomarker extraction in UK Biobank and Utah datasets, validated against expert annotations. Additionally, biAtriaNet showed high transferability to independent datasets, achieving Dice scores of 91.1% for LA and 88.6% for RA. Chamber volume estimates closely matched ground truth values (LA: 89.8 ± 33.0 ml versus 91.1 ± 41.2 ml; RA: 70.8 ± 16.9 ml versus 72.3 ± 20.5 ml) with >90% accuracy in chamber measurements. AWT accuracies were 95.9% for LA and 94.6% for RA, while fibrosis estimates showed Kolmogorov-Smirnov correlations of 86.3% (LA) and 90.6% (RA) (p < 0.05). By enabling robust bi-atrial segmentation and biomarker extraction from LGE-MRIs, biAtriaNet has the potential to enhance patient-specific AF treatment strategies.

Expert Systems with ApplicationsVol. 278
National Health Service (GB), St Bartholomew's Hospital (GB), University of Auckland (NZ), Queen Mary University of London (GB), Barts Health NHS Trust (GB), William Harvey Research Institute (GB), University of Waikato (NZ), The Ohio State University (US)
National Heart Foundation of New Zealand, Health Research Council of New Zealand
Openalex Percentile: Top 22%
Cardiac Imaging and Diagnostics
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.