Hydrolytic degradation studies of bio-composites of poly(L-lactic acid)/Oligo(L-lactic acid) grafted and non-grafted microcrystalline cellulose

This study investigates the hydrolytic degradation properties of poly( L -lactic acid) (PLLA)- based biodegradable polymer composites which were prepared with oligo( L -lactic acid) (OLLA) grafted and non-grafted microcrystalline cellulose (MCC) (OLLA-g-MCC and Non-g-MCC). MCC was obtained through the simple hydrolysis reaction of cellulose and then it was grafted with OLLA. The grafted MCC was characterized by FTIR, SEM and WAXD analyses. Composite of PLLA with OLLA-g-MCC (PLLA/OLLA-g-MCC) and Non-g-MCC (PLLA/Non-g-MCC) were prepared using the solution casting method. The hydrolytic degradation properties of composite samples were tested in a buffer solution at pH 7.4 and 37 °C. The changes in samples after degradation were monitored by analyzing the mechanical properties: thermal stability, crystallinity, degradability and making a comparison with that of PLLA. Both OLLA-g-MCC and Non-g-MCC enhanced the hydrolytic degradation of PLLA, which was observed by evaluating weight loss percentage. The initial weight loss rates of PLLA/OLLA-g-MCC (0.22 % day −1 ) and PLLA/Non-g-MCC (0.27 % day −1 ) were higher than that of PLLA (0.12 % day −1 ). The hydrolysis phenomenon is comparatively linear (Regression coefficient 0.9693) for PLLA, whereas nonlinearity is shown in the case of PLLA/Non-g-MCC composite. The PLLA/OLLA-g-MCC exhibits a higher K e than that of PLLA/Non-g-MCC and PLLA. The decline in pH indicates the generation of acidic substances. DSC shows that the degradation temperature of hydrolytically degraded samples declined sharply with hydrolytic degradation time up to 130 days and then the rate slowed down. Initial rapid increase in crystallinity was observed which may due to segmental mobility during hydrolytic degradation of the composites and polymer. • Composites of poly(L-lactic acid)/grafted, Non-grafted microcrystalline cellulose. • These cellulose enhance the hydrolytic degradation of the composites. • Composites weight loss rate is higher than poly(L-lactic acid). • Poly(L-lactic acid) show linear hydrolysis, nonlinearity is found in composites. • Increasing crystallinity due to segmental mobility during degradation.

Authors

Institutions

Publication Details

Journal
Next Materials
Published
2025-03-29
DOI
https://doi.org/10.1016/j.nxmate.2025.100615
Citations
1
Primary Topic
biodegradable polymer synthesis and properties
Type
article
Field-Weighted Citation Impact
0.60
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hydrolytic degradation studies of bio-composites of poly(L-lactic acid)/Oligo(L-lactic acid) grafted and non-grafted microcrystalline cellulose

S. Alam, Md Tauhidul Islam, Md. Aminur Rahman, Md. Hafezur Rahaman et al.
1 citations
Next Materials
biodegradable polymer synthesis and properties
0.60
article

Hydrolytic degradation studies of bio-composites of poly(L-lactic acid)/Oligo(L-lactic acid) grafted and non-grafted microcrystalline cellulose

S. Alam, Md Tauhidul Islam, Md. Aminur Rahman, Md. Hafezur Rahaman, G. M. Arifuzzaman Khan, Md. Ashraful Alam, Abu Rayhan
article en
1 citations

Abstract

This study investigates the hydrolytic degradation properties of poly( L -lactic acid) (PLLA)- based biodegradable polymer composites which were prepared with oligo( L -lactic acid) (OLLA) grafted and non-grafted microcrystalline cellulose (MCC) (OLLA-g-MCC and Non-g-MCC). MCC was obtained through the simple hydrolysis reaction of cellulose and then it was grafted with OLLA. The grafted MCC was characterized by FTIR, SEM and WAXD analyses. Composite of PLLA with OLLA-g-MCC (PLLA/OLLA-g-MCC) and Non-g-MCC (PLLA/Non-g-MCC) were prepared using the solution casting method. The hydrolytic degradation properties of composite samples were tested in a buffer solution at pH 7.4 and 37 °C. The changes in samples after degradation were monitored by analyzing the mechanical properties: thermal stability, crystallinity, degradability and making a comparison with that of PLLA. Both OLLA-g-MCC and Non-g-MCC enhanced the hydrolytic degradation of PLLA, which was observed by evaluating weight loss percentage. The initial weight loss rates of PLLA/OLLA-g-MCC (0.22 % day −1 ) and PLLA/Non-g-MCC (0.27 % day −1 ) were higher than that of PLLA (0.12 % day −1 ). The hydrolysis phenomenon is comparatively linear (Regression coefficient 0.9693) for PLLA, whereas nonlinearity is shown in the case of PLLA/Non-g-MCC composite. The PLLA/OLLA-g-MCC exhibits a higher K e than that of PLLA/Non-g-MCC and PLLA. The decline in pH indicates the generation of acidic substances. DSC shows that the degradation temperature of hydrolytically degraded samples declined sharply with hydrolytic degradation time up to 130 days and then the rate slowed down. Initial rapid increase in crystallinity was observed which may due to segmental mobility during hydrolytic degradation of the composites and polymer. • Composites of poly(L-lactic acid)/grafted, Non-grafted microcrystalline cellulose. • These cellulose enhance the hydrolytic degradation of the composites. • Composites weight loss rate is higher than poly(L-lactic acid). • Poly(L-lactic acid) show linear hydrolysis, nonlinearity is found in composites. • Increasing crystallinity due to segmental mobility during degradation.

Next MaterialsVol. 8
Bangladesh Council of Scientific and Industrial Research (BD), Islamic University (BD), University of Newcastle Australia (AU)
Clean water and sanitation
Openalex Percentile: Top 36%
biodegradable polymer synthesis and properties
0.60
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.