Noise exposure on surgeons using robotic surgical equipment for total knee arthroplasty

Objectives Occupational noise is a major issue in orthopedic surgery due to the prevalent use of power tools. In recent years, there has been a tremendous increase in the usage of robotic surgical equipment (RSE) in health care. One disadvantage of using RSE is the exposure to high noise levels for those in the vicinity of the robot. This study assessed noise levels associated with the Mako robotic surgical system in the performance of total knee replacement (TKR) surgeries. Methods Noise measurements were conducted using a dosimeter in the orthopedic operating room (OR). The maximum peak noise level (LCpeak) and the equivalent continuous noise level (LAeq = average sound level for a period of time) for each activity or piece of equipment were determined to estimate the daily dosage of noise (LEX, 8h) for OR personnel. Noise levels were assessed with reference to occupational noise regulations in Australia. Results The Mako robotic system produced the highest LAeq (89.5 dBA), while the maximum peak noise level was recorded during the use of the hammer (126.6 dBC). The surgeon was found to be exposed to the highest average sound level (LAeq), maximum peak noise level (LCpeak), and greatest daily dosage of noise (LEX, 8h). Conclusion As noisy equipment and instruments are used intermittently, the noise regulations were technically not exceeded when averaged throughout the session. However, noise levels in the OR were sufficiently high to warrant consideration of hearing protection for OR personnel during total knee arthroplasty, particularly for sessions where multiple surgeries are undertaken.

Authors

Institutions

Publication Details

Journal
Journal of Musculoskeletal Surgery and Research
Published
2025-03-28
DOI
https://doi.org/10.25259/jmsr_476_2024
Primary Topic
Noise Effects and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Noise exposure on surgeons using robotic surgical equipment for total knee arthroplasty

Mohammad A. Altayeb, Gabrielle Hawdon, Stephen McMahon, Christopher James Waterworth et al.
Journal of Musculoskeletal Surgery and Research
Noise Effects and Management
article

Noise exposure on surgeons using robotic surgical equipment for total knee arthroplasty

Mohammad A. Altayeb, Gabrielle Hawdon, Stephen McMahon, Christopher James Waterworth, Wing Kong Chiu, Manu Mathew, Matthew Adie
article en

Abstract

Objectives Occupational noise is a major issue in orthopedic surgery due to the prevalent use of power tools. In recent years, there has been a tremendous increase in the usage of robotic surgical equipment (RSE) in health care. One disadvantage of using RSE is the exposure to high noise levels for those in the vicinity of the robot. This study assessed noise levels associated with the Mako robotic surgical system in the performance of total knee replacement (TKR) surgeries. Methods Noise measurements were conducted using a dosimeter in the orthopedic operating room (OR). The maximum peak noise level (LCpeak) and the equivalent continuous noise level (LAeq = average sound level for a period of time) for each activity or piece of equipment were determined to estimate the daily dosage of noise (LEX, 8h) for OR personnel. Noise levels were assessed with reference to occupational noise regulations in Australia. Results The Mako robotic system produced the highest LAeq (89.5 dBA), while the maximum peak noise level was recorded during the use of the hammer (126.6 dBC). The surgeon was found to be exposed to the highest average sound level (LAeq), maximum peak noise level (LCpeak), and greatest daily dosage of noise (LEX, 8h). Conclusion As noisy equipment and instruments are used intermittently, the noise regulations were technically not exceeded when averaged throughout the session. However, noise levels in the OR were sufficiently high to warrant consideration of hearing protection for OR personnel during total knee arthroplasty, particularly for sessions where multiple surgeries are undertaken.

Journal of Musculoskeletal Surgery and ResearchVol. 9
The University of Melbourne (AU), Monash Health (AU), Monash University (AU)
Openalex Percentile: Top 92%
Noise Effects and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.