Improving radiation localization via energy-resolved angular photon responses

Results obtained from characterizing the capabilities of a collimated cerium bromide (CeBr 3 ) detector developed for use on robotic platforms are reported. The detector’s field-of-view is collimated by a lead slit, and experiments have been performed with point radiation sources configured in a-priori known geometric scenarios. The collimated detector is scanned over radiation sources using gimbal control, acquiring a spectrum at each angle to obtain energy-resolved angular responses. These responses are then approximated by mathematical transforms to enhance localization accuracy. Various combinations of radionuclides have been used to demonstrate the effectiveness of this approach. The results reveal that expressing X-ray and [Formula: see text]-ray angular responses with an appropriate transform improves the resolving power of the slit collimator. This technique offers distinct advantages in robot deployments by enabling additional in-situ characterization capabilities without imposing additional limitations or requirements.

Authors

Institutions

Publication Details

Journal
International Journal of Modern Physics E
Published
2025-03-28
DOI
https://doi.org/10.1142/s021830132545003x
Primary Topic
Advanced Optical Sensing Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving radiation localization via energy-resolved angular photon responses

Barry Lennox, Ioannis Tsitsimpelis, Francis R. Livens, Malcolm J. Joyce et al.
International Journal of Modern Physics E
Advanced Optical Sensing Technologies
article

Improving radiation localization via energy-resolved angular photon responses

Barry Lennox, Ioannis Tsitsimpelis, Francis R. Livens, Malcolm J. Joyce, C. James Taylor, Tilly L. Alton, Andrew West
article en

Abstract

Results obtained from characterizing the capabilities of a collimated cerium bromide (CeBr 3 ) detector developed for use on robotic platforms are reported. The detector’s field-of-view is collimated by a lead slit, and experiments have been performed with point radiation sources configured in a-priori known geometric scenarios. The collimated detector is scanned over radiation sources using gimbal control, acquiring a spectrum at each angle to obtain energy-resolved angular responses. These responses are then approximated by mathematical transforms to enhance localization accuracy. Various combinations of radionuclides have been used to demonstrate the effectiveness of this approach. The results reveal that expressing X-ray and [Formula: see text]-ray angular responses with an appropriate transform improves the resolving power of the slit collimator. This technique offers distinct advantages in robot deployments by enabling additional in-situ characterization capabilities without imposing additional limitations or requirements.

International Journal of Modern Physics EVol. 34(09)
University of Manchester (GB), Lancaster University (GB)
Affordable and clean energy
Openalex Percentile: Top 93%
Advanced Optical Sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Improving radiation localization via energy-resolved angular photon responses — Barry Lennox, Ioannis Tsitsimpelis, et al. · International Journal of Modern Physics E (2025) | TGRS Research Map | TGRS